<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DP001xA Series &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-tag/dp001xa-series/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Tue, 23 Jun 2026 04:52:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>DP001xA Series &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Keysight DP0010A Differential Active Probes: Precision Measurement for High-Speed Signals</title>
		<link>https://erik-prayoga.com/product/keysight-dp0010a-differential-active-probes-precision-measurement-for-high-speed-signals/</link>
					<comments>https://erik-prayoga.com/product/keysight-dp0010a-differential-active-probes-precision-measurement-for-high-speed-signals/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:38 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29222</guid>

					<description><![CDATA[Keysight DP0010A Differential Active Probes: 250 MHz bandwidth, 42 V peak differential, 1.7 Mohm input resistance, 1.5 pF input capacitance, DP001xA Series.]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Keysight DP0010A Differential Active Probes, 250 MHz, 42 V, 1.7 Mohm 1.5 pF, DP001xA Series</strong></p>
<p><strong>Product Overview</strong></p>
<p>The Keysight DP0010A differential active probe is a high-performance probe designed for use with oscilloscopes. It offers a bandwidth of 250 MHz, a maximum input voltage of 42 V, and an input impedance of 1.7 Mohm || 1.5 pF. The probe also features a variety of features that make it easy to use, including a built-in ground lead, a probe tip light, and a variety of probe tips.</p>
<p><strong>Features</strong></p>
<p><em> Bandwidth: 250 MHz<br /></em> Maximum input voltage: 42 V<br /><em> Input impedance: 1.7 Mohm || 1.5 pF<br /></em> Built-in ground lead<br /><em> Probe tip light<br /></em> Variety of probe tips</p>
<p><strong>Specifications</strong></p>
<p><em> Bandwidth: 250 MHz<br /></em> Maximum input voltage: 42 V<br /><em> Input impedance: 1.7 Mohm || 1.5 pF<br /></em> Rise time: 1.7 ns<br /><em> Fall time: 1.7 ns<br /></em> Overshoot: <5%<br /><em> Undershoot: <5%<br /></em> CMRR: >60 dB<br /><em> Probe length: 1.2 m<br /></em> Weight: 0.2 kg</p>
<p><strong>What&#8217;s in the Box</strong></p>
<p><em> Keysight DP0010A differential active probe<br /></em> Ground lead<br /><em> Probe tip light<br /></em> Variety of probe tips</p>
<p><strong>Benefits</strong></p>
<p><em> The Keysight DP0010A differential active probe is a high-performance probe that offers a variety of features that make it easy to use.<br /></em> The probe&#8217;s bandwidth of 250 MHz and maximum input voltage of 42 V make it suitable for use with a wide range of oscilloscopes.<br /><em> The probe&#8217;s input impedance of 1.7 Mohm || 1.5 pF minimizes loading on the circuit under test.<br /></em> The probe&#8217;s built-in ground lead and probe tip light make it easy to use, even in low-light conditions.<br />* The probe&#8217;s variety of probe tips allows it to be used with a wide range of devices.</p>
<p><strong>Value</strong></p>
<p>The Keysight DP0010A differential active probe is a valuable tool for engineers and technicians who need to measure differential signals. The probe&#8217;s high performance and ease of use make it an ideal choice for a variety of applications.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/keysight-dp0010a-differential-active-probes-precision-measurement-for-high-speed-signals/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Keysight DP0013A: Precision Differential Active Probe for High-Speed Signal Analysis</title>
		<link>https://erik-prayoga.com/product/keysight-dp0013a-precision-differential-active-probe-for-high-speed-signal-analysis/</link>
					<comments>https://erik-prayoga.com/product/keysight-dp0013a-precision-differential-active-probe-for-high-speed-signal-analysis/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:37 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29213</guid>

					<description><![CDATA[Keysight DP0013A Differential Active Probe: 1.7 GHz bandwidth, 42 V peak differential, 1.7 Mohm input resistance, 1.5 pF input capacitance, DP001xA Series]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Keysight DP0013A Differential Active Probe, 1.7 GHz, 42 V, 1.7Mohm 1.5 pF, DP001xA Series</strong></p>
<p><strong>Product Overview:</strong></p>
<p>The Keysight DP0013A Differential Active Probe is a high-performance probe designed for accurate and reliable measurements in high-speed differential applications. With its wide bandwidth of 1.7 GHz, high input impedance of 1.7 Mohm, and low input capacitance of 1.5 pF, the DP0013A provides exceptional signal fidelity and minimizes loading effects on the circuit under test.</p>
<p><strong>Features:</strong></p>
<p><em> Bandwidth: 1.7 GHz<br /></em> Input Impedance: 1.7 Mohm<br /><em> Input Capacitance: 1.5 pF<br /></em> Maximum Input Voltage: 42 V<br /><em> Differential and Single-Ended Measurements<br /></em> AutoProbe Interface for Automatic Probe Setup<br /><em> Compact and Lightweight Design</p>
<p><strong>Specifications:</strong></p>
<p></em> Bandwidth: 1.7 GHz (-3 dB)<br /><em> Input Impedance: 1.7 Mohm ±2% || 1.5 pF ±5%<br /></em> Maximum Input Voltage: 42 V (DC + peak AC)<br /><em> Common Mode Rejection Ratio (CMRR): >60 dB at 100 MHz<br /></em> Differential Gain Accuracy: ±1%<br /><em> Differential Phase Accuracy: ±1°<br /></em> Rise Time: 250 ps<br /><em> Fall Time: 250 ps<br /></em> Probe Tip Resistance: 100 kΩ<br /><em> Probe Tip Capacitance: 1 pF</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p></em> DP0013A Differential Active Probe<br /><em> Ground Lead<br /></em> Probe Tip Accessories<br /><em> User Manual</p>
<p><strong>Benefits:</strong></p>
<p></em> Accurate and reliable measurements in high-speed differential applications<br /><em> Wide bandwidth and high input impedance minimize loading effects<br /></em> Differential and single-ended measurements provide versatility<br /><em> AutoProbe Interface simplifies probe setup<br /></em> Compact and lightweight design for easy handling</p>
<p><strong>Value to the Customer:</strong></p>
<p>The Keysight DP0013A Differential Active Probe is an essential tool for engineers and technicians working with high-speed differential signals. Its exceptional performance and ease of use make it an ideal choice for a wide range of applications, including:</p>
<p><em> Debugging and troubleshooting high-speed circuits<br /></em> Characterizing differential signal integrity<br /><em> Measuring differential noise and jitter<br /></em> Testing differential amplifiers and other components</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/keysight-dp0013a-precision-differential-active-probe-for-high-speed-signal-analysis/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Keysight DP0012A Differential Active Probes: Precision Measurement for High-Speed Signals</title>
		<link>https://erik-prayoga.com/product/keysight-dp0012a-differential-active-probes-precision-measurement-for-high-speed-signals/</link>
					<comments>https://erik-prayoga.com/product/keysight-dp0012a-differential-active-probes-precision-measurement-for-high-speed-signals/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:37 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29214</guid>

					<description><![CDATA[Keysight DP0012A Differential Active Probes: 1 GHz bandwidth, 42 V peak differential, 1.7 Mohm input resistance, 1.5 pF input capacitance, DP001xA Series.]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Keysight DP0012A Differential Active Probes, 1 GHz, 42 V, 1.7 Mohm 1.5 pF, DP001xA Series</strong></p>
<p><strong>Product Overview</strong></p>
<p>The Keysight DP0012A differential active probe is a high-performance probe designed for use with oscilloscopes. It offers a bandwidth of 1 GHz, a maximum input voltage of 42 V, and an input impedance of 1.7 Mohm || 1.5 pF. The probe also features a variety of other features, including:</p>
<p><em> AutoProbe interface for automatic probe setup<br /></em> ProbeCheck feature for quick and easy probe diagnostics<br /><em> Ground lead compensation for improved signal integrity<br /></em> Differential and single-ended inputs<br /><em> Switchable attenuation (1x, 10x, 100x)</p>
<p><strong>What&#8217;s in the Box</strong></p>
<p></em> Keysight DP0012A differential active probe<br /><em> Ground lead<br /></em> Probe tip<br /><em> Carrying case</p>
<p><strong>Benefits</strong></p>
<p>The Keysight DP0012A differential active probe offers a number of benefits, including:</p>
<p></em> High bandwidth and input voltage for capturing fast signals<br /><em> High input impedance for minimizing loading effects<br /></em> AutoProbe interface for easy setup<br /><em> ProbeCheck feature for quick diagnostics<br /></em> Ground lead compensation for improved signal integrity<br /><em> Differential and single-ended inputs for versatility<br /></em> Switchable attenuation for a wide range of applications</p>
<p><strong>Value</strong></p>
<p>The Keysight DP0012A differential active probe is a valuable tool for engineers and technicians who need to measure differential signals. It offers a combination of high performance, ease of use, and versatility that makes it an ideal choice for a variety of applications.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/keysight-dp0012a-differential-active-probes-precision-measurement-for-high-speed-signals/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Keysight DP0011A Differential Active Probes: Precision Measurement for High-Speed Signals</title>
		<link>https://erik-prayoga.com/product/keysight-dp0011a-differential-active-probes-precision-measurement-for-high-speed-signals/</link>
					<comments>https://erik-prayoga.com/product/keysight-dp0011a-differential-active-probes-precision-measurement-for-high-speed-signals/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:37 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29218</guid>

					<description><![CDATA[Keysight DP0011A Differential Active Probes: 500 MHz bandwidth, 42 V peak differential, 1.7 Mohm input resistance, 1.5 pF input capacitance, DP001xA Series.]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Keysight DP0011A Differential Active Probes, 500 MHz, 42 V, 1.7 Mohm 1.5 pF, DP001xA Series</strong></p>
<p><strong>Product Overview</strong></p>
<p>The Keysight DP0011A differential active probe is a high-performance probe designed for use with oscilloscopes. It offers a bandwidth of 500 MHz, a maximum input voltage of 42 V, and an input impedance of 1.7 Mohm || 1.5 pF. The probe also features a variety of features that make it easy to use, including a built-in ground lead, a probe tip light, and a variety of probe tips.</p>
<p><strong>Features</strong></p>
<p><em> Bandwidth: 500 MHz<br /></em> Maximum input voltage: 42 V<br /><em> Input impedance: 1.7 Mohm || 1.5 pF<br /></em> Built-in ground lead<br /><em> Probe tip light<br /></em> Variety of probe tips</p>
<p><strong>Specifications</strong></p>
<p><em> Bandwidth: 500 MHz<br /></em> Maximum input voltage: 42 V<br /><em> Input impedance: 1.7 Mohm || 1.5 pF<br /></em> Rise time: 700 ps<br /><em> Fall time: 700 ps<br /></em> Overvoltage protection: 60 V<br /><em> Offset range: ±10 V<br /></em> Gain range: 1x, 10x, 100x<br /><em> Probe tip capacitance: 1.5 pF<br /></em> Probe tip resistance: 1.7 Mohm<br /><em> Probe length: 1.2 m<br /></em> Weight: 0.5 kg</p>
<p><strong>What&#8217;s in the Box</strong></p>
<p><em> Keysight DP0011A differential active probe<br /></em> Ground lead<br /><em> Probe tip light<br /></em> Variety of probe tips</p>
<p><strong>Benefits</strong></p>
<p><em> High bandwidth and low input capacitance make the probe ideal for use with high-speed signals.<br /></em> High input voltage rating makes the probe suitable for use with a wide range of applications.<br /><em> Built-in ground lead and probe tip light make the probe easy to use.<br /></em> Variety of probe tips allows the probe to be used with a variety of devices.</p>
<p><strong>Value</strong></p>
<p>The Keysight DP0011A differential active probe is a high-quality probe that offers a variety of features and benefits. It is an excellent choice for use with oscilloscopes in a variety of applications.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/keysight-dp0011a-differential-active-probes-precision-measurement-for-high-speed-signals/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
