<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>6m Cable &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-tag/6m-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Tue, 23 Jun 2026 04:52:09 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>6m Cable &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Teledyne LeCroy HVD3206A-6M: 2 kV, 80 MHz Differential Probe with Auto Zero and 6m Cable</title>
		<link>https://erik-prayoga.com/product/teledyne-lecroy-hvd3206a-6m-2-kv-80-mhz-differential-probe-with-auto-zero-and-6m-cable/</link>
					<comments>https://erik-prayoga.com/product/teledyne-lecroy-hvd3206a-6m-2-kv-80-mhz-differential-probe-with-auto-zero-and-6m-cable/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:51:57 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29102</guid>

					<description><![CDATA[Teledyne LeCroy HVD3206A-6M Differential Probe: 2 kV, 80 MHz, Auto Zero, 6m Cable, HVD3000A Series]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Teledyne LeCroy HVD3206A-6M Differential Probe</strong></p>
<p><strong>Product Overview:</strong></p>
<p>The Teledyne LeCroy HVD3206A-6M is a high-voltage differential probe designed for precise measurements in high-power electronics applications. With its 2 kV peak differential voltage rating and 80 MHz bandwidth, it enables accurate analysis of signals in power converters, motor drives, and other high-voltage systems.</p>
<p><strong>Features:</strong></p>
<p><em> <strong>High Voltage Rating:</strong> 2 kV peak differential voltage<br /></em> <strong>Wide Bandwidth:</strong> 80 MHz<br /><em> <strong>Auto Zero:</strong> Automatic zeroing for enhanced accuracy<br /></em> <strong>6m Cable:</strong> Long cable length for convenient measurements<br /><em> <strong>HVD3000A Series Compatibility:</strong> Compatible with all HVD3000A series probes<br /></em> <strong>Compact and Lightweight:</strong> Easy to handle and transport</p>
<p><strong>Specifications:</strong></p>
<p><em> <strong>Voltage Range:</strong> ±1 kV<br /></em> <strong>Bandwidth:</strong> DC to 80 MHz<br /><em> <strong>Input Impedance:</strong> 10 MΩ || 10 pF<br /></em> <strong>Common Mode Rejection Ratio (CMRR):</strong> >100 dB at DC<br /><em> <strong>Maximum Input Voltage:</strong> 2 kV peak differential<br /></em> <strong>Cable Length:</strong> 6m</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p><em> HVD3206A-6M Differential Probe<br /></em> Ground Lead<br /><em> Probe Tip<br /></em> User Manual</p>
<p><strong>Benefits:</strong></p>
<p><em> <strong>Accurate High-Voltage Measurements:</strong> Enables precise analysis of signals in high-power electronics systems.<br /></em> <strong>Wide Bandwidth:</strong> Captures fast transients and high-frequency components.<br /><em> <strong>Auto Zero:</strong> Ensures accurate measurements by automatically compensating for offset errors.<br /></em> <strong>Long Cable Length:</strong> Provides flexibility and convenience during measurements.<br />* <strong>HVD3000A Series Compatibility:</strong> Integrates seamlessly with other HVD3000A series probes for expanded measurement capabilities.</p>
<p><strong>Value to the Customer:</strong></p>
<p>The Teledyne LeCroy HVD3206A-6M Differential Probe is an essential tool for engineers and technicians working with high-voltage electronics. Its high voltage rating, wide bandwidth, and auto zeroing capabilities ensure accurate and reliable measurements, enabling efficient troubleshooting and design optimization.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/teledyne-lecroy-hvd3206a-6m-2-kv-80-mhz-differential-probe-with-auto-zero-and-6m-cable/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Teledyne LeCroy HVD3106A-6M: 1 kV, 80 MHz Differential Probe with Auto Zero and 6m Cable</title>
		<link>https://erik-prayoga.com/product/teledyne-lecroy-hvd3106a-6m-1-kv-80-mhz-differential-probe-with-auto-zero-and-6m-cable/</link>
					<comments>https://erik-prayoga.com/product/teledyne-lecroy-hvd3106a-6m-1-kv-80-mhz-differential-probe-with-auto-zero-and-6m-cable/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:51:57 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29104</guid>

					<description><![CDATA[Teledyne LeCroy HVD3106A-6M Differential Probe: 1 kV, 80 MHz, Auto Zero, 6m Cable, HVD3000A Series]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Teledyne LeCroy HVD3106A-6M Differential Probe</strong></p>
<p><strong>Product Overview:</strong></p>
<p>The Teledyne LeCroy HVD3106A-6M is a high-voltage differential probe designed for precise measurements in high-power electronics applications. With its wide bandwidth and high input voltage range, it enables accurate analysis of fast-changing signals in power converters, motor drives, and other industrial systems.</p>
<p><strong>Features:</strong></p>
<p><em> <strong>High Input Voltage Range:</strong> ±1 kV differential, ±2 kV common mode<br /></em> <strong>Wide Bandwidth:</strong> 80 MHz<br /><em> <strong>Auto Zero:</strong> Automatic offset correction for enhanced accuracy<br /></em> <strong>6m Cable:</strong> Long cable length for convenient measurements in large systems<br /><em> <strong>HVD3000A Series Compatibility:</strong> Compatible with all HVD3000A series probes for versatile use</p>
<p><strong>Specifications:</strong></p>
<p></em> Input Impedance: 10 MΩ || 10 pF<br /><em> CMRR: >100 dB at 50 Hz<br /></em> Input Offset Voltage: <10 mV<br /><em> Rise Time: <5 ns<br /></em> Maximum Input Current: 10 mA<br /><em> Operating Temperature: 0°C to 50°C</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p></em> HVD3106A-6M Differential Probe<br /><em> Ground Lead<br /></em> Probe Tip<br /><em> User Manual</p>
<p><strong>Benefits:</strong></p>
<p></em> <strong>Accurate Measurements:</strong> High input voltage range and wide bandwidth ensure precise signal capture in high-power environments.<br /><em> <strong>Convenient Operation:</strong> Auto zero feature simplifies setup and eliminates offset errors.<br /></em> <strong>Versatile Use:</strong> Compatibility with HVD3000A series probes allows for easy integration into existing measurement systems.<br />* <strong>Enhanced Safety:</strong> High input voltage range and long cable length provide safe and convenient measurements in hazardous environments.</p>
<p><strong>Value to the Customer:</strong></p>
<p>The Teledyne LeCroy HVD3106A-6M Differential Probe empowers engineers with the ability to perform accurate and reliable measurements in high-voltage applications. Its advanced features and ease of use make it an indispensable tool for troubleshooting, design verification, and performance analysis in power electronics systems.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/teledyne-lecroy-hvd3106a-6m-1-kv-80-mhz-differential-probe-with-auto-zero-and-6m-cable/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
