<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>5X/50X &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-tag/5x-50x/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Tue, 23 Jun 2026 04:52:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>5X/50X &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Tektronix TDP0500: High-Voltage Differential Probe for Precision Measurements</title>
		<link>https://erik-prayoga.com/product/tektronix-tdp0500-high-voltage-differential-probe-for-precision-measurements/</link>
					<comments>https://erik-prayoga.com/product/tektronix-tdp0500-high-voltage-differential-probe-for-precision-measurements/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:19 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29174</guid>

					<description><![CDATA[Tektronix TDP0500 High Voltage Differential Probe: 500 MHz bandwidth, 5X/50X attenuation, 1 pF capacitance, TekVPI interface, 1.2m cable length, TDP Series]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Tektronix TDP0500 High Voltage Differential Probe, 500 MHz, 5X/50X, 1 pF, TekVPI, 1.2m, TDP Series</strong></p>
<p><strong>Product Overview:</strong></p>
<p>The Tektronix TDP0500 is a high-voltage differential probe designed for use with oscilloscopes. It offers a wide bandwidth of 500 MHz, making it suitable for capturing fast-changing signals. The probe has a switchable attenuation ratio of 5X/50X, allowing it to measure signals with a wide range of amplitudes. The TDP0500 also features a low input capacitance of 1 pF, minimizing loading effects on the circuit under test.</p>
<p><strong>Features:</strong></p>
<p><em> High voltage differential probe<br /></em> Bandwidth: 500 MHz<br /><em> Attenuation ratio: 5X/50X<br /></em> Input capacitance: 1 pF<br /><em> TekVPI interface<br /></em> Cable length: 1.2m</p>
<p><strong>Specifications:</strong></p>
<p><em> <strong>Bandwidth:</strong> 500 MHz<br /></em> <strong>Attenuation ratio:</strong> 5X/50X<br /><em> <strong>Input capacitance:</strong> 1 pF<br /></em> <strong>Input resistance:</strong> 10 MΩ<br /><em> <strong>Maximum input voltage:</strong> ±1000 V (DC + peak AC)<br /></em> <strong>Common mode rejection ratio:</strong> >80 dB at 500 MHz<br /><em> <strong>Probe tip spacing:</strong> 1.5 mm<br /></em> <strong>Cable length:</strong> 1.2m<br /><em> <strong>Weight:</strong> 0.5 kg</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p></em> Tektronix TDP0500 High Voltage Differential Probe<br /><em> Ground lead<br /></em> Probe tip accessories<br /><em> User manual</p>
<p><strong>Benefits:</strong></p>
<p></em> Accurately measure high-voltage differential signals<br /><em> Wide bandwidth for capturing fast-changing signals<br /></em> Switchable attenuation ratio for measuring signals with a wide range of amplitudes<br /><em> Low input capacitance minimizes loading effects<br /></em> TekVPI interface for easy connection to oscilloscopes</p>
<p><strong>Value to the Customer:</strong></p>
<p>The Tektronix TDP0500 High Voltage Differential Probe is a valuable tool for engineers and technicians who need to measure high-voltage differential signals. Its wide bandwidth, switchable attenuation ratio, and low input capacitance make it suitable for a variety of applications, including power electronics, automotive testing, and industrial control.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/tektronix-tdp0500-high-voltage-differential-probe-for-precision-measurements/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tektronix TDP1000: High-Voltage Differential Probe for Precision Measurements</title>
		<link>https://erik-prayoga.com/product/tektronix-tdp1000-high-voltage-differential-probe-for-precision-measurements/</link>
					<comments>https://erik-prayoga.com/product/tektronix-tdp1000-high-voltage-differential-probe-for-precision-measurements/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:18 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29172</guid>

					<description><![CDATA[Tektronix TDP1000 High Voltage Differential Probe: 1 GHz bandwidth, 5X/50X attenuation, 1 pF capacitance, 42 V peak differential, TekVPI interface, TDP Series]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Tektronix TDP1000 High Voltage Differential Probe, 1 GHz, 5X/50X, 1 pF, 42 V, TekVPI, TDP Series</strong></p>
<p><strong>Product Overview:</strong></p>
<p>The Tektronix TDP1000 is a high-voltage differential probe designed for use with oscilloscopes. It offers a wide bandwidth of 1 GHz, making it suitable for capturing fast signals. The probe has a switchable attenuation of 5X or 50X, allowing it to measure signals with a wide range of amplitudes. The TDP1000 also features a low input capacitance of 1 pF, which minimizes loading on the circuit under test.</p>
<p><strong>Features:</strong></p>
<p><em> Bandwidth: 1 GHz<br /></em> Attenuation: 5X/50X<br /><em> Input capacitance: 1 pF<br /></em> Maximum input voltage: 42 V<br /><em> TekVPI interface<br /></em> Auto-ranging<br /><em> Offset adjustment<br /></em> Ground reference indicator</p>
<p><strong>Specifications:</strong></p>
<p><em> Bandwidth: 1 GHz<br /></em> Attenuation: 5X/50X<br /><em> Input capacitance: 1 pF<br /></em> Maximum input voltage: 42 V<br /><em> Rise time: 350 ps<br /></em> Fall time: 350 ps<br /><em> Offset range: ±10 V<br /></em> Offset accuracy: ±1%<br /><em> Common mode rejection ratio: >80 dB<br /></em> Power supply: TekVPI interface</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p><em> Tektronix TDP1000 High Voltage Differential Probe<br /></em> Ground lead<br /><em> Probe tip<br /></em> User manual</p>
<p><strong>Benefits:</strong></p>
<p><em> High bandwidth for capturing fast signals<br /></em> Switchable attenuation for measuring signals with a wide range of amplitudes<br /><em> Low input capacitance for minimizing loading on the circuit under test<br /></em> TekVPI interface for easy connection to oscilloscopes<br /><em> Auto-ranging for quick and easy setup<br /></em> Offset adjustment for precise signal positioning<br />* Ground reference indicator for easy identification of the ground connection</p>
<p><strong>Value to the Customer:</strong></p>
<p>The Tektronix TDP1000 High Voltage Differential Probe is a valuable tool for engineers and technicians who need to measure high-voltage differential signals. It offers a wide range of features and specifications that make it suitable for a variety of applications. The probe&#8217;s high bandwidth, low input capacitance, and switchable attenuation make it an ideal choice for measuring fast signals with a wide range of amplitudes. The TekVPI interface makes it easy to connect the probe to oscilloscopes, and the auto-ranging and offset adjustment features make it quick and easy to set up.</p>