<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>50:1 &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-tag/501/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Tue, 23 Jun 2026 04:52:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>50:1 &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Keysight N2805A: High-Voltage Differential Probe for Precision Measurements</title>
		<link>https://erik-prayoga.com/product/keysight-n2805a-high-voltage-differential-probe-for-precision-measurements/</link>
					<comments>https://erik-prayoga.com/product/keysight-n2805a-high-voltage-differential-probe-for-precision-measurements/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:38 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29220</guid>

					<description><![CDATA[Keysight N2805A High-Voltage Differential Probe: 200 MHz bandwidth, 50:1 attenuation, 4M ohm/4 pF input impedance, high CMRR, ideal for high-voltage differential measurements.]]></description>
										<content:encoded><![CDATA[<p><strong>Keysight N2805A High-Voltage Differential Probe</strong></p>
<p><strong>Features and Specifications:</strong></p>
<p><em> Bandwidth: 200 MHz<br /></em> Attenuation: 50:1<br /><em> Input Resistance: 4 MΩ<br /></em> Input Capacitance: 4 pF<br /><em> Common Mode Rejection Ratio (CMRR): >100 dB at 50 Hz<br /></em> Maximum Input Voltage: ±1400 V (DC + peak AC)<br /><em> Probe Tip Length: 10 cm<br /></em> Probe Tip Diameter: 2.5 mm<br /><em> Probe Length: 1.5 m</p>
<p><strong>Product Overview:</strong></p>
<p>The Keysight N2805A High-Voltage Differential Probe is designed for high-voltage measurements in power electronics, automotive, and industrial applications. It offers a wide bandwidth of 200 MHz, high input resistance of 4 MΩ, and low input capacitance of 4 pF, making it ideal for capturing fast transients and high-frequency signals. The probe&#8217;s high CMRR ensures accurate measurements even in the presence of common mode noise.</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p></em> N2805A High-Voltage Differential Probe<br /><em> Ground lead<br /></em> Probe tip accessories<br /><em> User manual</p>
<p><strong>Benefits:</strong></p>
<p></em> Accurately measure high-voltage signals up to ±1400 V<br /><em> Capture fast transients and high-frequency signals with 200 MHz bandwidth<br /></em> Minimize loading effects with high input resistance and low input capacitance<br /><em> Reduce noise and improve signal integrity with high CMRR<br /></em> Easily connect to test points with 10 cm probe tip length and 2.5 mm probe tip diameter</p>
<p><strong>Value to the Customer:</strong></p>
<p>The Keysight N2805A High-Voltage Differential Probe provides engineers with a reliable and accurate tool for high-voltage measurements. Its combination of high performance, ease of use, and affordability makes it an essential tool for any engineer working with power electronics, automotive, or industrial applications.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/keysight-n2805a-high-voltage-differential-probe-for-precision-measurements/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Keysight DP0001A: High-Voltage Differential Probe for Precision Measurements</title>
		<link>https://erik-prayoga.com/product/keysight-dp0001a-high-voltage-differential-probe-for-precision-measurements/</link>
					<comments>https://erik-prayoga.com/product/keysight-dp0001a-high-voltage-differential-probe-for-precision-measurements/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:37 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29210</guid>

					<description><![CDATA[Keysight DP0001A High-Voltage Differential Probe: 400 MHz bandwidth, 50:1/100:1/250:1/500:1 attenuation ratios, 50 Ohm impedance, differential and common mode measurements, floating inputs, high CMRR, low noise, wide dynamic range, safety features.]]></description>
										<content:encoded><![CDATA[<p><strong>Keysight DP0001A High-Voltage Differential Probe</strong></p>
<p><strong>Features and Specifications:</strong></p>
<p><em> Bandwidth: 400 MHz<br /></em> Attenuation: 50:1, 100:1, 250:1, 500:1<br /><em> Input Impedance: 50 Ohm<br /></em> Maximum Input Voltage: 1000 V (DC + peak AC)<br /><em> Rise Time: < 875 ps<br /></em> Input Capacitance: < 1.5 pF<br /><em> Probe Length: 1.5 m<br /></em> Weight: 0.5 kg</p>
<p><strong>Product Overview:</strong></p>
<p>The Keysight DP0001A High-Voltage Differential Probe is designed for high-voltage measurements in power electronics, automotive, and industrial applications. It offers a wide bandwidth of 400 MHz and a high input impedance of 50 Ohm, ensuring accurate and reliable measurements. The probe&#8217;s adjustable attenuation ratios (50:1, 100:1, 250:1, 500:1) allow for a wide range of input voltages to be measured.</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p><em> DP0001A High-Voltage Differential Probe<br /></em> Ground lead<br /><em> Probe tip<br /></em> User manual</p>
<p><strong>Benefits:</strong></p>
<p><em> <strong>High-voltage measurement capability:</strong> Safely measure voltages up to 1000 V.<br /></em> <strong>Wide bandwidth:</strong> Capture fast-changing signals with a bandwidth of 400 MHz.<br /><em> <strong>Adjustable attenuation:</strong> Optimize signal levels for accurate measurements.<br /></em> <strong>Low input capacitance:</strong> Minimize loading effects on the circuit under test.<br />* <strong>Compact and lightweight:</strong> Easy to handle and transport.</p>
<p><strong>Value to the Customer:</strong></p>
<p>The Keysight DP0001A High-Voltage Differential Probe provides engineers with a reliable and versatile tool for high-voltage measurements. Its combination of high performance, ease of use, and affordability makes it an essential tool for any engineer working with power electronics, automotive, or industrial applications.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/keysight-dp0001a-high-voltage-differential-probe-for-precision-measurements/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
