<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>100X/1000X &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-tag/100x-1000x/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Tue, 23 Jun 2026 04:52:39 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>100X/1000X &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Tektronix P5210A: High-Voltage Differential Probe for Precision Measurements</title>
		<link>https://erik-prayoga.com/product/tektronix-p5210a-high-voltage-differential-probe-for-precision-measurements/</link>
					<comments>https://erik-prayoga.com/product/tektronix-p5210a-high-voltage-differential-probe-for-precision-measurements/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:36 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29195</guid>

					<description><![CDATA[Tektronix P5210A High-Voltage Differential Probe: 50 MHz bandwidth, 100X/1000X attenuation, 2.5 pF input capacitance, 5600V peak differential voltage, P52xxA Series.]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications</strong></p>
<p><strong>Tektronix P5210A High-Voltage Differential Probe, 50 MHz, 100X/1000X, 2.5 pF, 5600V, P52xxA Series</strong></p>
<p><strong>Product Overview</strong></p>
<p>The Tektronix P5210A is a high-voltage differential probe designed for use with oscilloscopes. It offers a wide bandwidth of 50 MHz, high input impedance of 10 MΩ, and low input capacitance of 2.5 pF. The P5210A also features a maximum input voltage of 5600V, making it ideal for use in high-voltage applications.</p>
<p><strong>Features</strong></p>
<p><em> High-voltage differential probe<br /></em> 50 MHz bandwidth<br /><em> 10 MΩ input impedance<br /></em> 2.5 pF input capacitance<br /><em> Maximum input voltage of 5600V<br /></em> Auto-ranging<br /><em> Ground referencing<br /></em> Probe tip light<br /><em> Rugged construction</p>
<p><strong>Specifications</strong></p>
<p></em> Bandwidth: 50 MHz<br /><em> Input impedance: 10 MΩ<br /></em> Input capacitance: 2.5 pF<br /><em> Maximum input voltage: 5600V<br /></em> CMRR: >80 dB at 50 MHz<br /><em> Probe tip length: 10 cm<br /></em> Probe tip diameter: 2.5 mm<br /><em> Weight: 250 g<br /></em> Dimensions: 200 x 50 x 25 mm</p>
<p><strong>What&#8217;s in the Box</strong></p>
<p><em> Tektronix P5210A High-Voltage Differential Probe<br /></em> Ground lead<br /><em> Probe tip<br /></em> User manual</p>
<p><strong>Benefits</strong></p>
<p><em> The Tektronix P5210A is a high-quality, high-voltage differential probe that is ideal for use in a variety of applications.<br /></em> Its wide bandwidth, high input impedance, and low input capacitance make it ideal for use with oscilloscopes.<br /><em> Its maximum input voltage of 5600V makes it ideal for use in high-voltage applications.<br /></em> The P5210A is also auto-ranging, ground referencing, and has a probe tip light, making it easy to use.<br />* Its rugged construction makes it ideal for use in harsh environments.</p>
<p><strong>Value</strong></p>
<p>The Tektronix P5210A is a valuable tool for engineers and technicians who need to measure high-voltage signals. Its high quality, wide bandwidth, and high input impedance make it ideal for use in a variety of applications. Its maximum input voltage of 5600V makes it ideal for use in high-voltage applications. The P5210A is also auto-ranging, ground referencing, and has a probe tip light, making it easy to use. Its rugged construction makes it ideal for use in harsh environments.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/tektronix-p5210a-high-voltage-differential-probe-for-precision-measurements/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tektronix THDP0100: High-Voltage Differential Probe for Precision Measurements</title>
		<link>https://erik-prayoga.com/product/tektronix-thdp0100-high-voltage-differential-probe-for-precision-measurements/</link>
					<comments>https://erik-prayoga.com/product/tektronix-thdp0100-high-voltage-differential-probe-for-precision-measurements/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:52:36 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29197</guid>

					<description><![CDATA[Tektronix THDP0100 High Voltage Differential Probe: 100 MHz bandwidth, 100X/1000X attenuation, 2.5 pF input capacitance, 6000V peak differential voltage, THDP Series.]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Tektronix THDP0100 High Voltage Differential Probe, 100 MHz, 100X/1000X, 2.5 pF, 6000V, THDP Series</strong></p>
<p><strong>Product Overview:</strong></p>
<p>The Tektronix THDP0100 is a high-performance differential probe designed for accurate and reliable measurements in high-voltage applications. With its wide bandwidth of 100 MHz, high input impedance of 100 MΩ, and low input capacitance of 2.5 pF, the THDP0100 provides exceptional signal fidelity and minimizes loading effects on the circuit under test.</p>
<p><strong>Features:</strong></p>
<p><em> High voltage rating of 6000V (DC + peak AC)<br /></em> Selectable attenuation ratios of 100X and 1000X<br /><em> Wide bandwidth of 100 MHz<br /></em> High input impedance of 100 MΩ<br /><em> Low input capacitance of 2.5 pF<br /></em> Ground reference compensation<br /><em> Auto-zero function<br /></em> Compact and lightweight design</p>
<p><strong>Specifications:</strong></p>
<p><em> Bandwidth: 100 MHz<br /></em> Input Impedance: 100 MΩ<br /><em> Input Capacitance: 2.5 pF<br /></em> Attenuation Ratios: 100X, 1000X<br /><em> Maximum Input Voltage: 6000V (DC + peak AC)<br /></em> Common Mode Rejection Ratio (CMRR): >80 dB at 50 Hz<br /><em> Probe Length: 1.5 m (5 ft)</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p></em> THDP0100 High Voltage Differential Probe<br /><em> Ground lead<br /></em> Probe tip<br /><em> User manual</p>
<p><strong>Benefits:</strong></p>
<p></em> Accurately measure high-voltage signals with confidence<br /><em> Minimize loading effects on the circuit under test<br /></em> Capture fast transients and high-frequency components<br /><em> Improve signal-to-noise ratio and reduce measurement uncertainty<br /></em> Enhance productivity with auto-zero and ground reference compensation features</p>
<p><strong>Value to the Customer:</strong></p>
<p>The Tektronix THDP0100 High Voltage Differential Probe is an essential tool for engineers and technicians working with high-voltage systems. Its exceptional performance and ease of use enable accurate and reliable measurements, saving time and reducing the risk of errors. By providing a clear view of high-voltage signals, the THDP0100 empowers users to optimize system performance, troubleshoot problems, and ensure safety.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/tektronix-thdp0100-high-voltage-differential-probe-for-precision-measurements/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
