<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>0.6 pF &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-tag/0-6-pf/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Tue, 23 Jun 2026 04:52:08 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>0.6 pF &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Teledyne LeCroy ZS4000: The Ultimate 4 GHz Active Probe for Precision Measurements</title>
		<link>https://erik-prayoga.com/product/teledyne-lecroy-zs4000-the-ultimate-4-ghz-active-probe-for-precision-measurements/</link>
					<comments>https://erik-prayoga.com/product/teledyne-lecroy-zs4000-the-ultimate-4-ghz-active-probe-for-precision-measurements/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:51:57 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29094</guid>

					<description><![CDATA[Teledyne LeCroy ZS4000 Active Probe: 4 GHz bandwidth, 0.6 pF capacitance, 1 Mohm impedance, 8/12 V power supply, ProBus interface, ZS Series.]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Teledyne LeCroy ZS4000 Active Probe, 4 GHz, 0.6 pF, 1 Mohm, 8/12 V, ProBus, ZS Series</strong></p>
<p><strong>Product Overview:</strong></p>
<p>The Teledyne LeCroy ZS4000 Active Probe is a high-performance probe designed for use with oscilloscopes. It offers a wide bandwidth of 4 GHz, a low input capacitance of 0.6 pF, and a high input resistance of 1 Mohm. The probe is powered by either 8 or 12 V and features ProBus compatibility for easy connection to LeCroy oscilloscopes.</p>
<p><strong>Features:</strong></p>
<p><em> Bandwidth: 4 GHz<br /></em> Input capacitance: 0.6 pF<br /><em> Input resistance: 1 Mohm<br /></em> Power supply: 8 or 12 V<br /><em> ProBus compatibility<br /></em> Compact and lightweight design</p>
<p><strong>Specifications:</strong></p>
<p><em> Bandwidth: 4 GHz<br /></em> Input capacitance: 0.6 pF<br /><em> Input resistance: 1 Mohm<br /></em> Power supply: 8 or 12 V<br /><em> ProBus compatibility<br /></em> Dimensions: 1.5 x 1.5 x 4.5 inches<br /><em> Weight: 4 ounces</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p></em> Teledyne LeCroy ZS4000 Active Probe<br /><em> Ground lead<br /></em> Probe tip<br /><em> Carrying case</p>
<p><strong>Benefits:</strong></p>
<p></em> High bandwidth for accurate measurements of high-speed signals<br /><em> Low input capacitance for minimal loading on the circuit under test<br /></em> High input resistance for accurate voltage measurements<br /><em> ProBus compatibility for easy connection to LeCroy oscilloscopes<br /></em> Compact and lightweight design for easy portability</p>
<p><strong>Value:</strong></p>
<p>The Teledyne LeCroy ZS4000 Active Probe is a valuable tool for engineers and technicians who need to make accurate measurements of high-speed signals. Its high bandwidth, low input capacitance, and high input resistance make it ideal for use in a variety of applications, including:</p>
<p><em> Digital design<br /></em> Power electronics<br /><em> Telecommunications<br /></em> Aerospace and defense</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/teledyne-lecroy-zs4000-the-ultimate-4-ghz-active-probe-for-precision-measurements/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Teledyne LeCroy DL02-HCM: Precision Differential Probe for High-Speed Signal Analysis</title>
		<link>https://erik-prayoga.com/product/teledyne-lecroy-dl02-hcm-precision-differential-probe-for-high-speed-signal-analysis/</link>
					<comments>https://erik-prayoga.com/product/teledyne-lecroy-dl02-hcm-precision-differential-probe-for-high-speed-signal-analysis/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 04:51:57 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/?post_type=product&#038;p=29103</guid>

					<description><![CDATA[Teledyne LeCroy DL02-HCM Differential Probe: 250 MHz bandwidth, 7.8X/17.5X/70X attenuation, 0.6 pF input capacitance, 60 V max input voltage, ProBus interface, DL-HCM Series]]></description>
										<content:encoded><![CDATA[<p><strong>Features and Specifications: Teledyne LeCroy DL02-HCM Differential Probe, 250 MHz, 7.8X/17.5X/70X, 0.6 pF, 60 V, ProBus, DL-HCM Series</strong></p>
<p><strong>Product Overview:</strong></p>
<p>The Teledyne LeCroy DL02-HCM Differential Probe is a high-performance probe designed for use with oscilloscopes. It offers a wide range of features and specifications that make it ideal for a variety of applications, including:</p>
<p><em> <strong>Bandwidth:</strong> 250 MHz<br /></em> <strong>Attenuation:</strong> 7.8X/17.5X/70X<br /><em> <strong>Input Capacitance:</strong> 0.6 pF<br /></em> <strong>Maximum Input Voltage:</strong> 60 V<br /><em> <strong>ProBus Interface:</strong> Yes<br /></em> <strong>DL-HCM Series:</strong> Yes</p>
<p><strong>Features:</strong></p>
<p><em> High bandwidth and low input capacitance for accurate signal acquisition<br /></em> Selectable attenuation for a wide range of input signals<br /><em> ProBus interface for easy connection to oscilloscopes<br /></em> Rugged construction for durability in harsh environments</p>
<p><strong>Specifications:</strong></p>
<p><em> <strong>Bandwidth:</strong> 250 MHz<br /></em> <strong>Attenuation:</strong> 7.8X/17.5X/70X<br /><em> <strong>Input Capacitance:</strong> 0.6 pF<br /></em> <strong>Maximum Input Voltage:</strong> 60 V<br /><em> <strong>ProBus Interface:</strong> Yes<br /></em> <strong>DL-HCM Series:</strong> Yes<br /><em> <strong>Dimensions:</strong> 120 mm x 30 mm x 15 mm<br /></em> <strong>Weight:</strong> 100 g</p>
<p><strong>What&#8217;s in the Box:</strong></p>
<p><em> DL02-HCM Differential Probe<br /></em> Ground Lead<br /><em> Probe Tip<br /></em> User Manual</p>
<p><strong>Benefits:</strong></p>
<p><em> Accurate signal acquisition with high bandwidth and low input capacitance<br /></em> Versatile use with selectable attenuation<br /><em> Easy connection to oscilloscopes with ProBus interface<br /></em> Durable construction for long-lasting performance</p>
<p><strong>Value to the Customer:</strong></p>
<p>The Teledyne LeCroy DL02-HCM Differential Probe is a valuable tool for engineers and technicians who need to accurately measure and analyze differential signals. Its high performance and versatility make it ideal for a wide range of applications, from design and development to troubleshooting and repair.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/teledyne-lecroy-dl02-hcm-precision-differential-probe-for-high-speed-signal-analysis/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
