<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Submersible Level Transmitters &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-category/sensors-instrumentation/submersible-level-transmitters/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Mon, 22 Jun 2026 17:51:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>Submersible Level Transmitters &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Dwyer Mercoid PBLT2-20-60 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mercoid-pblt22060-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mercoid-pblt22060-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:53 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mercoid-pblt2-20-60-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer Mercoid PBLT2-20-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Built in Lightning Protection. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories: A-625…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer Mercoid PBLT2-20-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Built in Lightning Protection. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories: A-625 Cable Hanger, A-297 Dessicant Filter.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Size</th>
<td>3.4375&quot;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Protective Cage</td>
</tr>
<tr>
<th>(Instrument-Sensor) Output Signal Type</th>
<td>4-20 Ma 2 Wire (Loop Powered)</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Dirty Liquids</td>
</tr>
<tr>
<th>(Instrument-Sensor) Span</th>
<td>46&#39;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 °F &#8211; 200 °F</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>12 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mercoid-pblt22060-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer PBLT2-5-60 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-pblt2560-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-pblt2560-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:52 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-pblt2-5-60-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer PBLT2-5-60 is a submersible level transmitter with a temperature range of 0 to 200°F (-18 to 93°C). It offers an accuracy of ±0.25% FS and operates on a power requirement of 13 to 30 VDC. With an IP68 enclosure rating and a response time of 50 msec, this transmitter is designed for use in hazardous locations.…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer PBLT2-5-60 is a submersible level transmitter with a temperature range of 0 to 200°F (-18 to 93°C). It offers an accuracy of ±0.25% FS and operates on a power requirement of 13 to 30 VDC. With an IP68 enclosure rating and a response time of 50 msec, this transmitter is designed for use in hazardous locations. The output signal is 4 to 20 mA DC, and it is suitable for measuring compatible liquids. The wetted materials include 316 SS and 316L SS for the body, with polyether polyurethane or ETFE for the cable and fluoroelastomer seals. It has a pressure limit of 2X FS and a thermal effect of ±0.02% FS/°F. The electrical connections are wire pigtail, and the loop resistance is 900 Ω.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) IP Protection</th>
<td>IP68</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Liquid</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>10 &#8211; 28 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>13 &#8211; 30 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 176 °F/-20 &#8211; 80°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 &#8211; 200 °F/-18 &#8211; 93°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 149 °F/-20 &#8211; 65°C</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-pblt2560-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer Mercoid PBLT2-15-60 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mercoid-pblt21560-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mercoid-pblt21560-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:52 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mercoid-pblt2-15-60-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer Mercoid PBLT2-15-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Built in Lightning Protection. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories: A-625…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer Mercoid PBLT2-15-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Built in Lightning Protection. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories: A-625 Cable Hanger, A-297 Dessicant Filter.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Size</th>
<td>3.4375&quot;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Protective Cage</td>
</tr>
<tr>
<th>(Instrument-Sensor) Output Signal Type</th>
<td>4-20 Ma 2 Wire (Loop Powered)</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Dirty Liquids</td>
</tr>
<tr>
<th>(Instrument-Sensor) Span</th>
<td>34&#39;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 °F &#8211; 200 °F</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>12 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mercoid-pblt21560-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer Mercoid FBLT-2SC-IVEF-30-50 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mercoid-fblt2scivef3050-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mercoid-fblt2scivef3050-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:51 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mercoid-fblt-2sc-ivef-30-50-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer Mercoid FBLT-2SC-IVEF-30-50 Submersible Level Transmitter Series FBLT Flush Tip Diaphram Submersible Level Transmitter. Perfect for dirty applications like Sludge and Slurries. Flush, non-clogging diaphragm great for dirty applications. Vent has maintenance free filter to prevent particalate or water drops from…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer Mercoid FBLT-2SC-IVEF-30-50 Submersible Level Transmitter Series FBLT Flush Tip Diaphram Submersible Level Transmitter. Perfect for dirty applications like Sludge and Slurries. Flush, non-clogging diaphragm great for dirty applications. Vent has maintenance free filter to prevent particalate or water drops from entering transmitter. Recommended Accessories: A-297 Dessicant Filter.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Output Signal Type</th>
<td>4-20 Ma 2 Wire (Loop Powered)</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Dirty Liquids</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Bullet Nose</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Slim Bore</td>
</tr>
<tr>
<th>(Instrument-Sensor) Size</th>
<td>1.1875&quot;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Span</th>
<td>69&#39;</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>12 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 °F &#8211; 176 °F</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Long operating life with a non-clog flush diaphragm tip for harsh applications</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Suits harsh environments with choice of polyether polyurethane or ETFE cable materials for excellent chemical compatibility</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty)</p>
<p>Meet application requirements with narrow body design allows the FBLT to fit into stilling wells and narrow installations</p>
<p>Unit holds up in aggressive fluids with robust FKM fluoroelastomer diaphragm that is PTFE coated for a stick-resistant surface</p>
<p>Avoid product leaks typically cause by oil or grease with diaphragm cavity that is filled with gel</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use the A-625 hanging loop to attach a chain to remove from the installation</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mercoid-fblt2scivef3050-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer PBLT2-10-60 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-pblt21060-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-pblt21060-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:51 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-pblt2-10-60-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer PBLT2-10-60 is a submersible level transmitter with a temperature range of 0 to 200°F. It offers ±0.25% FS accuracy, 50 msec response time, and an IP68 enclosure rating. With 4-20 mA DC output, it is ideal for measuring compatible liquids in hazardous locations.</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer PBLT2-10-60 is a submersible level transmitter with a temperature range of 0 to 200°F. It offers ±0.25% FS accuracy, 50 msec response time, and an IP68 enclosure rating. With 4-20 mA DC output, it is ideal for measuring compatible liquids in hazardous locations.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) IP Protection</th>
<td>IP68</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Liquid</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>10 &#8211; 28 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>13 &#8211; 30 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 176 °F/-20 &#8211; 80°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 &#8211; 200 °F/-18 &#8211; 93°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 149 °F/-20 &#8211; 65°C</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-pblt21060-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer Mercoid MBLT-2SC-IVPF-200-220 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mercoid-mblt2scivpf200220-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mercoid-mblt2scivpf200220-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:50 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mercoid-mblt-2sc-ivpf-200-220-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer Mercoid MBLT-2SC-IVPF-200-220 Submersible Level Transmitter Series MBLT Miniature Submersible Level Transmitter. Slim Bore only 0.63″ in Diameter. Slim design great for tight boreholes and well applications. Submersible Level Transmitter for Clean Applications. Vent has maintenance free filter to prevent…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer Mercoid MBLT-2SC-IVPF-200-220 Submersible Level Transmitter Series MBLT Miniature Submersible Level Transmitter. Slim Bore only 0.63&quot; in Diameter. Slim design great for tight boreholes and well applications. Submersible Level Transmitter for Clean Applications. Vent has maintenance free filter to prevent particalate or water drops from entering transmitter. Recommended Accessories: A-297 Dessicant Filter.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Output Signal Type</th>
<td>4-20 Ma 2 Wire (Loop Powered)</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Bullet Nose</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Slim Bore</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Clean Liquids</td>
</tr>
<tr>
<th>(Instrument-Sensor) Span</th>
<td>150&#39;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.10%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Size</th>
<td>0.63&quot;</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>12 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 °F &#8211; 176 °F</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Slender 0.63˝ (16 mm) diameter design fits in narrow openings</p>
<p>Constructed for years of trouble free service with welded 316 SS body and 316 SS nose cap</p>
<p>Body top is 316 SS and tapered to prevent damage or snares when pulling the unit out of the installation</p>
<p>Low power voltage output models are ideal for remote level monitoring with rechargeable battery and solar panel</p>
<p>Maintenance free filter on vent tube eliminates particulate water droplets from entering the transducer</p>
<p>Incorporates lightning and surge protection, eliminating both power supply surges and lightning ground strike transients</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mercoid-mblt2scivpf200220-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer PBLT2-15-80 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-pblt21580-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-pblt21580-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:48 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-pblt2-15-80-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer PBLT2-15-80 is a submersible level transmitter suitable for hazardous locations. It has a temperature range of 0 to 200°F (-18 to 93°C) and a ±0.25% FS accuracy. The transmitter operates on a power supply of 13 to 30 VDC and has a quick response time of 50 msec. It features an IP68 enclosure rating and offers a…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer PBLT2-15-80 is a submersible level transmitter suitable for hazardous locations. It has a temperature range of 0 to 200°F (-18 to 93°C) and a ±0.25% FS accuracy. The transmitter operates on a power supply of 13 to 30 VDC and has a quick response time of 50 msec. It features an IP68 enclosure rating and offers a 4 to 20 mA DC output signal. The unit is designed to be suspended in the tank below the level being measured and is compatible with various liquids. The wetted materials include 316 SS, 316L SS, and fluoroelastomer seals. The pressure limit is 2X FS, and the thermal effect is ±0.02% FS/°F. The transmitter is protected against lightning and surges (PBLT2) and has a loop resistance of 900 Ω.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) IP Protection</th>
<td>IP68</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Liquid</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>10 &#8211; 28 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>13 &#8211; 30 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 176 °F/-20 &#8211; 80°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 &#8211; 200 °F/-18 &#8211; 93°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 149 °F/-20 &#8211; 65°C</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-pblt21580-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer PBLT2-10-80 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-pblt21080-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-pblt21080-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:48 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-pblt2-10-80-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer PBLT2-10-80 is a submersible level transmitter suitable for measuring liquid levels. It has a temperature range of 0 to 200°F and an accuracy of ±0.25% FS. The transmitter operates on a power requirement of 13 to 30 VDC and has a quick response time of 50 msec. It is encased in an IP68 rated enclosure and…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer PBLT2-10-80 is a submersible level transmitter suitable for measuring liquid levels. It has a temperature range of 0 to 200°F and an accuracy of ±0.25% FS. The transmitter operates on a power requirement of 13 to 30 VDC and has a quick response time of 50 msec. It is encased in an IP68 rated enclosure and features a 4 to 20 mA DC output signal. The transmitter is designed for suspended mounting in tanks and is made from 316 SS and 316L SS body materials with polyether polyurethane or ETFE cable and fluoroelastomer seals. It can withstand a pressure limit of 2X FS and is suitable for hazardous locations. The thermal effect is ±0.02% FS/°F and has a loop resistance of 900 Ω. The PBLT2-10-80 is equipped with lightning and surge protection for electrical safety.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) IP Protection</th>
<td>IP68</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Liquid</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>10 &#8211; 28 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>13 &#8211; 30 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 176 °F/-20 &#8211; 80°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 &#8211; 200 °F/-18 &#8211; 93°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 149 °F/-20 &#8211; 65°C</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-pblt21080-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer MBLT-2SB-IVPF-150-170 Miniature Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mblt2sbivpf150170-miniature-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mblt2sbivpf150170-miniature-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:48 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mblt-2sb-ivpf-150-170-miniature-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer MBLT-2SB-IVPF-150-170 is a miniature submersible level transmitter suitable for monitoring compatible liquids. It has a temperature range of -4 to 176°F, with an accuracy of ±0.25% or ±0.10% FS. Its power requirement is 10 to 33 VDC for current output and 8 to 33 VDC for voltage output. It offers a fast response…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer MBLT-2SB-IVPF-150-170 is a miniature submersible level transmitter suitable for monitoring compatible liquids. It has a temperature range of -4 to 176°F, with an accuracy of ±0.25% or ±0.10% FS. Its power requirement is 10 to 33 VDC for current output and 8 to 33 VDC for voltage output. It offers a fast response time of under 50 ms and features a 4 to 20 mA DC 2-wire output signal. With a pressure limit of 2x FS, it can withstand harsh conditions. The compact transmitter is easy to mount and comes with surge and lightning protection for enhanced durability.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Liquid</td>
</tr>
<tr>
<th>Component</th>
<td>Miniature Submersible Level Transmitter</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>10 &#8211; 33 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>8 &#8211; 33 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 176 °F/-20 &#8211; 80°C</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Slender 0.63˝ (16 mm) diameter design fits in narrow openings</p>
<p>Constructed for years of trouble free service with welded 316 SS body and 316 SS nose cap</p>
<p>Body top is 316 SS and tapered to prevent damage or snares when pulling the unit out of the installation</p>
<p>Low power voltage output models are ideal for remote level monitoring with rechargeable battery and solar panel</p>
<p>Maintenance free filter on vent tube eliminates particulate water droplets from entering the transducer</p>
<p>Incorporates lightning and surge protection, eliminating both power supply surges and lightning ground strike transients</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mblt2sbivpf150170-miniature-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer Mercoid PBLTX-15-60 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mercoid-pbltx1560-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mercoid-pbltx1560-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:47 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mercoid-pbltx-15-60-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer Mercoid PBLTX-15-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Class 1 Div 1 intrinsically safe. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories:…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer Mercoid PBLTX-15-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Class 1 Div 1 intrinsically safe. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories: A-625 Cable Hanger, A-297 Dessicant Filter.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Size</th>
<td>3.4375&quot;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Protective Cage</td>
</tr>
<tr>
<th>(Instrument-Sensor) Output Signal Type</th>
<td>4-20 Ma 2 Wire (Loop Powered)</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Dirty Liquids</td>
</tr>
<tr>
<th>(Instrument-Sensor) Span</th>
<td>34&#39;</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument-Sensor) Hazardous Location Class</th>
<td>Class I Div. I Intrinsically Safe</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>12 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 °F &#8211; 176 °F</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mercoid-pbltx1560-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
