<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Level Switches &amp; Transmitters &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-category/sensors-instrumentation/level-switches-transmitters/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Tue, 23 Jun 2026 02:19:21 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>Level Switches &amp; Transmitters &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Dwyer TFLS-W11SR1-048 Tuning Fork Level Switch</title>
		<link>https://erik-prayoga.com/product/dwyer-tflsw11sr1048-tuning-fork-level-switch/</link>
					<comments>https://erik-prayoga.com/product/dwyer-tflsw11sr1048-tuning-fork-level-switch/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 02:19:21 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-tfls-w11sr1-048-tuning-fork-level-switch/</guid>

					<description><![CDATA[<p>Dwyer TFLS-W11SR1-048 Tuning Fork Level Switch is a weatherproof, NEMA 4X rated device designed for detecting bulk materials submerged in liquid. It operates in ambient temperatures ranging from -4 to 140°F (-20 to 60°C) and requires 90 to 265 VAC or 24 VDC power. With a wetted material of 316 SS and pressure limit of…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer TFLS-W11SR1-048 Tuning Fork Level Switch is a weatherproof, NEMA 4X rated device designed for detecting bulk materials submerged in liquid. It operates in ambient temperatures ranging from -4 to 140°F (-20 to 60°C) and requires 90 to 265 VAC or 24 VDC power. With a wetted material of 316 SS and pressure limit of 145 psig (10 bar), it offers reliable performance. The switch features a SPDT switch type, has a process connection of 1-1/2&quot; male NPT, and an enclosure made of aluminum, powder coated material. It consumes 4 VA of power and has an electrical rating of 5 A @ 230 VAC. The sensitivity is adjustable and the time delay settings can be adjusted from 2 to 20 seconds. It also includes indication lights for easy monitoring.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>(Instrument-Sensor) NEMA Protection</th>
<td>NEMA 4X</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Bulk Solids</td>
</tr>
<tr>
<th>Component</th>
<td>Level Switch</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Dry Powder</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Tuning Fork</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>90 &#8211; 265 VAC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>Ambient: -4 &#8211; 140 °F/-20 &#8211; 60°C</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Status indication with external LED switch indicator, and internal indicators for normal and alarm status</p>
<p>No calibration required for quick and easy installation</p>
<p>No mechanical moving parts with no routine maintenance required</p>
<p>Unaffected by the dielectric constant of the sensed material, making it superior to a capacitance level switch for applications where the dielectric constant is too low, where there is more than one material being used in one vessel, and when material moisture content can change</p>
<p>Vibrating fork design is ideal for low bulk density and low dielectric constant products, detecting products down to 1.8 lb/ft3 (30 g/l)</p>
<p>Ideal for applications where the bulk density is too low for a rotating paddle level switch</p>
<p>Adjustable sensitivity can be set to ignore lighter bulk density products and only detect heavier products, such as sand, gravel, or polyester chips in water</p>
<p>Unit is not affected by vibration from conveying systems, motors, or the movement of material</p>
<p>Mounted in any position and is available with factory built extensions for mounting on the top of the storage vessel</p>
<p>Failsafe setting with output switch that can be set for NO or NC condition on loss of power</p>
<p>Time delay prevents false alarms from material surges</p>
<p>Universal power supply yields one model which works with 90-265 VAC and 24 VDC</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-tflsw11sr1048-tuning-fork-level-switch/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer TFLS-W11SR1-036 Tuning Fork Level Switch</title>
		<link>https://erik-prayoga.com/product/dwyer-tflsw11sr1036-tuning-fork-level-switch/</link>
					<comments>https://erik-prayoga.com/product/dwyer-tflsw11sr1036-tuning-fork-level-switch/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 02:19:20 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-tfls-w11sr1-036-tuning-fork-level-switch/</guid>

					<description><![CDATA[<p>Dwyer TFLS-W11SR1-036 Tuning Fork Level Switch is a weatherproof, NEMA 4X rated switch designed to detect bulk materials submerged in liquid. It has a wide temperature range of -4 to 140°F (-20 to 60°C) and power requirements of 90 to 265 VAC or 24 VDC. With an enclosure made of aluminum, powder coated material, it…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer TFLS-W11SR1-036 Tuning Fork Level Switch is a weatherproof, NEMA 4X rated switch designed to detect bulk materials submerged in liquid. It has a wide temperature range of -4 to 140°F (-20 to 60°C) and power requirements of 90 to 265 VAC or 24 VDC. With an enclosure made of aluminum, powder coated material, it ensures durability. The switch has a sensitivity for a minimum bulk density of 1.8 lb/ft³ (30 g/l) and a maximum particle size of 0.4&quot; (10 mm). Additional features include adjustable time delays, indication lights, and a SPDT switch type.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>(Instrument-Sensor) NEMA Protection</th>
<td>NEMA 4X</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Bulk Solids</td>
</tr>
<tr>
<th>Component</th>
<td>Level Switch</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Dry Powder</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Tuning Fork</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>90 &#8211; 265 VAC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>Ambient: -4 &#8211; 140 °F/-20 &#8211; 60°C</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Status indication with external LED switch indicator, and internal indicators for normal and alarm status</p>
<p>No calibration required for quick and easy installation</p>
<p>No mechanical moving parts with no routine maintenance required</p>
<p>Unaffected by the dielectric constant of the sensed material, making it superior to a capacitance level switch for applications where the dielectric constant is too low, where there is more than one material being used in one vessel, and when material moisture content can change</p>
<p>Vibrating fork design is ideal for low bulk density and low dielectric constant products, detecting products down to 1.8 lb/ft3 (30 g/l)</p>
<p>Ideal for applications where the bulk density is too low for a rotating paddle level switch</p>
<p>Adjustable sensitivity can be set to ignore lighter bulk density products and only detect heavier products, such as sand, gravel, or polyester chips in water</p>
<p>Unit is not affected by vibration from conveying systems, motors, or the movement of material</p>
<p>Mounted in any position and is available with factory built extensions for mounting on the top of the storage vessel</p>
<p>Failsafe setting with output switch that can be set for NO or NC condition on loss of power</p>
<p>Time delay prevents false alarms from material surges</p>
<p>Universal power supply yields one model which works with 90-265 VAC and 24 VDC</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-tflsw11sr1036-tuning-fork-level-switch/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer F7-MLK2 Level Switches &#8211; Horizontal/Specialty</title>
		<link>https://erik-prayoga.com/product/dwyer-f7mlk2-level-switches-horizontalspecialty/</link>
					<comments>https://erik-prayoga.com/product/dwyer-f7mlk2-level-switches-horizontalspecialty/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 02:19:18 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-f7-mlk2-level-switches-horizontal-specialty/</guid>

					<description><![CDATA[<p>Dwyer F7-MLK2 is a horizontal/specialty level switch with an enclosure rating of general purpose. It has various mounting options and is compatible with liquids. The switch has a pressure limit of 218 psi and an electrical rating of 20 VA. The specific gravity and magnet type vary depending on the model.</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer F7-MLK2 is a horizontal/specialty level switch with an enclosure rating of general purpose. It has various mounting options and is compatible with liquids. The switch has a pressure limit of 218 psi and an electrical rating of 20 VA. The specific gravity and magnet type vary depending on the model.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Liquid</td>
</tr>
<tr>
<th>Component</th>
<td>Level Switch</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Horizontal/Specialty</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 257 °F/-20 &#8211; 125°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>14 &#8211; 176 °F/-10 &#8211; 80°C</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-f7mlk2-level-switches-horizontalspecialty/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer 201-WT-7810-C1-60 Chamber type level control</title>
		<link>https://erik-prayoga.com/product/dwyer-201wt7810c160-chamber-type-level-control/</link>
					<comments>https://erik-prayoga.com/product/dwyer-201wt7810c160-chamber-type-level-control/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Tue, 23 Jun 2026 02:19:17 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-201-wt-7810-c1-60-chamber-type-level-control/</guid>

					<description><![CDATA[<p>Chamber type level control, side mounted, SPDT snap switch.</p>]]></description>
										<content:encoded><![CDATA[<p>Chamber type level control, side mounted, SPDT snap switch.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Chamber Type Level Control</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-201wt7810c160-chamber-type-level-control/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer Mercoid PBLT2-20-60 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mercoid-pblt22060-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mercoid-pblt22060-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:53 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mercoid-pblt2-20-60-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer Mercoid PBLT2-20-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Built in Lightning Protection. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories: A-625…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer Mercoid PBLT2-20-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Built in Lightning Protection. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories: A-625 Cable Hanger, A-297 Dessicant Filter.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Size</th>
<td>3.4375&quot;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Protective Cage</td>
</tr>
<tr>
<th>(Instrument-Sensor) Output Signal Type</th>
<td>4-20 Ma 2 Wire (Loop Powered)</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Dirty Liquids</td>
</tr>
<tr>
<th>(Instrument-Sensor) Span</th>
<td>46&#39;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 °F &#8211; 200 °F</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>12 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mercoid-pblt22060-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer PBLT2-5-60 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-pblt2560-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-pblt2560-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:52 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-pblt2-5-60-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer PBLT2-5-60 is a submersible level transmitter with a temperature range of 0 to 200°F (-18 to 93°C). It offers an accuracy of ±0.25% FS and operates on a power requirement of 13 to 30 VDC. With an IP68 enclosure rating and a response time of 50 msec, this transmitter is designed for use in hazardous locations.…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer PBLT2-5-60 is a submersible level transmitter with a temperature range of 0 to 200°F (-18 to 93°C). It offers an accuracy of ±0.25% FS and operates on a power requirement of 13 to 30 VDC. With an IP68 enclosure rating and a response time of 50 msec, this transmitter is designed for use in hazardous locations. The output signal is 4 to 20 mA DC, and it is suitable for measuring compatible liquids. The wetted materials include 316 SS and 316L SS for the body, with polyether polyurethane or ETFE for the cable and fluoroelastomer seals. It has a pressure limit of 2X FS and a thermal effect of ±0.02% FS/°F. The electrical connections are wire pigtail, and the loop resistance is 900 Ω.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) IP Protection</th>
<td>IP68</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Liquid</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>10 &#8211; 28 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>13 &#8211; 30 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 176 °F/-20 &#8211; 80°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 &#8211; 200 °F/-18 &#8211; 93°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 149 °F/-20 &#8211; 65°C</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-pblt2560-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer Mercoid PBLT2-15-60 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mercoid-pblt21560-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mercoid-pblt21560-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:52 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mercoid-pblt2-15-60-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer Mercoid PBLT2-15-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Built in Lightning Protection. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories: A-625…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer Mercoid PBLT2-15-60 Submersible Level Transmitter Series SBLTX Dirty Liquid Submersible Level Transmitter. Built in Lightning Protection. Perfect for Sludge and Slurries. Dirty Application Submersible Level Transmitter for dirty applications like wastewater and slurry applications. Recommended Accessories: A-625 Cable Hanger, A-297 Dessicant Filter.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Size</th>
<td>3.4375&quot;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Protective Cage</td>
</tr>
<tr>
<th>(Instrument-Sensor) Output Signal Type</th>
<td>4-20 Ma 2 Wire (Loop Powered)</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Dirty Liquids</td>
</tr>
<tr>
<th>(Instrument-Sensor) Span</th>
<td>34&#39;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 °F &#8211; 200 °F</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>12 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mercoid-pblt21560-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer Mercoid FBLT-2SC-IVEF-30-50 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mercoid-fblt2scivef3050-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mercoid-fblt2scivef3050-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:51 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mercoid-fblt-2sc-ivef-30-50-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer Mercoid FBLT-2SC-IVEF-30-50 Submersible Level Transmitter Series FBLT Flush Tip Diaphram Submersible Level Transmitter. Perfect for dirty applications like Sludge and Slurries. Flush, non-clogging diaphragm great for dirty applications. Vent has maintenance free filter to prevent particalate or water drops from…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer Mercoid FBLT-2SC-IVEF-30-50 Submersible Level Transmitter Series FBLT Flush Tip Diaphram Submersible Level Transmitter. Perfect for dirty applications like Sludge and Slurries. Flush, non-clogging diaphragm great for dirty applications. Vent has maintenance free filter to prevent particalate or water drops from entering transmitter. Recommended Accessories: A-297 Dessicant Filter.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Output Signal Type</th>
<td>4-20 Ma 2 Wire (Loop Powered)</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Dirty Liquids</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Bullet Nose</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Slim Bore</td>
</tr>
<tr>
<th>(Instrument-Sensor) Size</th>
<td>1.1875&quot;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Span</th>
<td>69&#39;</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>12 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 °F &#8211; 176 °F</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Long operating life with a non-clog flush diaphragm tip for harsh applications</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Suits harsh environments with choice of polyether polyurethane or ETFE cable materials for excellent chemical compatibility</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty)</p>
<p>Meet application requirements with narrow body design allows the FBLT to fit into stilling wells and narrow installations</p>
<p>Unit holds up in aggressive fluids with robust FKM fluoroelastomer diaphragm that is PTFE coated for a stick-resistant surface</p>
<p>Avoid product leaks typically cause by oil or grease with diaphragm cavity that is filled with gel</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use the A-625 hanging loop to attach a chain to remove from the installation</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mercoid-fblt2scivef3050-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer PBLT2-10-60 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-pblt21060-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-pblt21060-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:51 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-pblt2-10-60-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer PBLT2-10-60 is a submersible level transmitter with a temperature range of 0 to 200°F. It offers ±0.25% FS accuracy, 50 msec response time, and an IP68 enclosure rating. With 4-20 mA DC output, it is ideal for measuring compatible liquids in hazardous locations.</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer PBLT2-10-60 is a submersible level transmitter with a temperature range of 0 to 200°F. It offers ±0.25% FS accuracy, 50 msec response time, and an IP68 enclosure rating. With 4-20 mA DC output, it is ideal for measuring compatible liquids in hazardous locations.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.25%</td>
</tr>
<tr>
<th>(Instrument-Sensor) IP Protection</th>
<td>IP68</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Liquid</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>10 &#8211; 28 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>13 &#8211; 30 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 176 °F/-20 &#8211; 80°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>0 &#8211; 200 °F/-18 &#8211; 93°C</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 &#8211; 149 °F/-20 &#8211; 65°C</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Meet application requirements with durable cage design with large diameter 316 SS diaphragm seal that is non-clogging and damage resistant to floating solids</p>
<p>Increased life with lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on PBLT2 models</p>
<p>Eliminates particulate or water droplets from entering the transducer using maintenance-free filter</p>
<p>Peace of mind with UL approved intrinsically safe on PBLTX models for use in hazardous locations when used with proper barrier</p>
<p>Decrease ownership cost with durable, 270 lb tensile strength shielded and vented cable and excellent chemical compatibility</p>
<p>Flexible installation options with NPT connection to rigidly install in a pipe/conduit or use a A-625 hanging loop to attach a chain to remove from the installation</p>
<p>Minimal downtime with standard 72 hour lead time</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-pblt21060-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Dwyer Mercoid MBLT-2SC-IVPF-200-220 Submersible Level Transmitter</title>
		<link>https://erik-prayoga.com/product/dwyer-mercoid-mblt2scivpf200220-submersible-level-transmitter/</link>
					<comments>https://erik-prayoga.com/product/dwyer-mercoid-mblt2scivpf200220-submersible-level-transmitter/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 17:51:50 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/dwyer-mercoid-mblt-2sc-ivpf-200-220-submersible-level-transmitter/</guid>

					<description><![CDATA[<p>Dwyer Mercoid MBLT-2SC-IVPF-200-220 Submersible Level Transmitter Series MBLT Miniature Submersible Level Transmitter. Slim Bore only 0.63″ in Diameter. Slim design great for tight boreholes and well applications. Submersible Level Transmitter for Clean Applications. Vent has maintenance free filter to prevent…</p>]]></description>
										<content:encoded><![CDATA[<p>Dwyer Mercoid MBLT-2SC-IVPF-200-220 Submersible Level Transmitter Series MBLT Miniature Submersible Level Transmitter. Slim Bore only 0.63&quot; in Diameter. Slim design great for tight boreholes and well applications. Submersible Level Transmitter for Clean Applications. Vent has maintenance free filter to prevent particalate or water drops from entering transmitter. Recommended Accessories: A-297 Dessicant Filter.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Submersible Level Transmitter</td>
</tr>
<tr>
<th>(Instrument-Sensor) Output Signal Type</th>
<td>4-20 Ma 2 Wire (Loop Powered)</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Bullet Nose</td>
</tr>
<tr>
<th>(Instrument-Sensor) Type</th>
<td>Slim Bore</td>
</tr>
<tr>
<th>(Instrument-Sensor) Application</th>
<td>Clean Liquids</td>
</tr>
<tr>
<th>(Instrument-Sensor) Span</th>
<td>150&#39;</td>
</tr>
<tr>
<th>(Instrument-Sensor) Measurement Accuracy</th>
<td>0.10%</td>
</tr>
<tr>
<th>(Instrument-Sensor) Size</th>
<td>0.63&quot;</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Dwyer Instruments</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>12 VDC</td>
</tr>
<tr>
<th>(Instrument &#8211; Sensor) Supply Voltage</th>
<td>24 VDC</td>
</tr>
<tr>
<th>(Instrument-Sensor) Temperature Range</th>
<td>-4 °F &#8211; 176 °F</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Slender 0.63˝ (16 mm) diameter design fits in narrow openings</p>
<p>Constructed for years of trouble free service with welded 316 SS body and 316 SS nose cap</p>
<p>Body top is 316 SS and tapered to prevent damage or snares when pulling the unit out of the installation</p>
<p>Low power voltage output models are ideal for remote level monitoring with rechargeable battery and solar panel</p>
<p>Maintenance free filter on vent tube eliminates particulate water droplets from entering the transducer</p>
<p>Incorporates lightning and surge protection, eliminating both power supply surges and lightning ground strike transients</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/dwyer-mercoid-mblt2scivpf200220-submersible-level-transmitter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>