<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Networking Thermal Management &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-category/networking-communication/networking-thermal-management/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Mon, 22 Jun 2026 06:28:52 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>Networking Thermal Management &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>nVent Hoffman PTHW242424GF 25.0&#8243;x24.0&#8243;x25.0&#8243; ProTek Double-Hinged Fan Packages</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-pthw242424gf-250x240x250-protek-doublehinged-fan-packages/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-pthw242424gf-250x240x250-protek-doublehinged-fan-packages/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:52 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-pthw242424gf-25-0x24-0x25-0-protek-double-hinged-fan-packages/</guid>

					<description><![CDATA[<p>nVent Hoffman PTHW242424GF 25.0″x24.0″x25.0″ Wall Mount ProTek Double-Hinged Fan Packages</p>]]></description>
										<content:encoded><![CDATA[<p>nVent Hoffman PTHW242424GF 25.0&quot;x24.0&quot;x25.0&quot; Wall Mount ProTek Double-Hinged Fan Packages</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Fan Package</td>
</tr>
<tr>
<th>Thermal Component Height</th>
<td>25.0&quot;</td>
</tr>
<tr>
<th>Thermal Component Width</th>
<td>24.0&quot;</td>
</tr>
<tr>
<th>Thermal Component Rack Units</th>
<td>12</td>
</tr>
<tr>
<th>Line</th>
<td>Protek</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Window door, made of .25-inch scratch-resistant safety glass and mechanically fastened, provides visual monitoring of internal equipment while maintaining equipment protection</p>
<p>Integral top solar/drip shield</p>
<p>Two thermostatically controlled, long-life, high-performance fans mounted into top</p>
<p>All seams are fully welded and ground smooth</p>
<p>Solid door provides complete physical and visual protection</p>
<p>Front and rear access to 19-inch rack equipment provided by three-part design: door, center section and wall section</p>
<p>Perforated, vented base with internal, expanded metal, serviceable filter</p>
<p>One set of plated, self-grounding, tapped 10-32 rack angles per EIA universal spacing standards, adjustable front-to-back within the center section of the cabinet</p>
<p>Key-locking wing knob provides access control to the cabinet, two keys are included with each cabinet</p>
<p>Premium seamless, foam-in-place gasket prevents contaminants from entering the cabinet</p>
<p>Door, center section and wall section are provided with ground studs to facilitate proper bonding and grounding of the cabinet</p>
<p>Additional rack angles in tapped- or square-hole versions can be added to the cabinet</p>
<p>Wall section welded panel studs which accommodate standard panels (steel and wood available), can be ordered separately</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-pthw242424gf-250x240x250-protek-doublehinged-fan-packages/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>nVent Hoffman PTHW362424GF 37.0&#8243;x24.0&#8243;x25.0&#8243; ProTek Double-Hinged Fan Packages</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-pthw362424gf-370x240x250-protek-doublehinged-fan-packages/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-pthw362424gf-370x240x250-protek-doublehinged-fan-packages/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:51 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-pthw362424gf-37-0x24-0x25-0-protek-double-hinged-fan-packages/</guid>

					<description><![CDATA[<p>nVent Hoffman PTHW362424GF 37.0″x24.0″x25.0″ Wall Mount ProTek Double-Hinged Fan Packages</p>]]></description>
										<content:encoded><![CDATA[<p>nVent Hoffman PTHW362424GF 37.0&quot;x24.0&quot;x25.0&quot; Wall Mount ProTek Double-Hinged Fan Packages</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Fan Package</td>
</tr>
<tr>
<th>Thermal Component Width</th>
<td>24.0&quot;</td>
</tr>
<tr>
<th>Thermal Component Height</th>
<td>37.0&quot;</td>
</tr>
<tr>
<th>Thermal Component Rack Units</th>
<td>19</td>
</tr>
<tr>
<th>Line</th>
<td>Protek</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Window door, made of .25-inch scratch-resistant safety glass and mechanically fastened, provides visual monitoring of internal equipment while maintaining equipment protection</p>
<p>Integral top solar/drip shield</p>
<p>Two thermostatically controlled, long-life, high-performance fans mounted into top</p>
<p>All seams are fully welded and ground smooth</p>
<p>Solid door provides complete physical and visual protection</p>
<p>Front and rear access to 19-inch rack equipment provided by three-part design: door, center section and wall section</p>
<p>Perforated, vented base with internal, expanded metal, serviceable filter</p>
<p>One set of plated, self-grounding, tapped 10-32 rack angles per EIA universal spacing standards, adjustable front-to-back within the center section of the cabinet</p>
<p>Key-locking wing knob provides access control to the cabinet, two keys are included with each cabinet</p>
<p>Premium seamless, foam-in-place gasket prevents contaminants from entering the cabinet</p>
<p>Door, center section and wall section are provided with ground studs to facilitate proper bonding and grounding of the cabinet</p>
<p>Additional rack angles in tapped- or square-hole versions can be added to the cabinet</p>
<p>Wall section welded panel studs which accommodate standard panels (steel and wood available), can be ordered separately</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-pthw362424gf-370x240x250-protek-doublehinged-fan-packages/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>nVent Hoffman PTHW482424GF 49.0&#8243;x24.0&#8243;x25.0&#8243; ProTek Double-Hinged Fan Packages</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-pthw482424gf-490x240x250-protek-doublehinged-fan-packages/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-pthw482424gf-490x240x250-protek-doublehinged-fan-packages/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:50 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-pthw482424gf-49-0x24-0x25-0-protek-double-hinged-fan-packages/</guid>

					<description><![CDATA[<p>nVent Hoffman PTHW482424GF 49.0″x24.0″x25.0″ Wall Mount ProTek Double-Hinged Fan Packages</p>]]></description>
										<content:encoded><![CDATA[<p>nVent Hoffman PTHW482424GF 49.0&quot;x24.0&quot;x25.0&quot; Wall Mount ProTek Double-Hinged Fan Packages</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Fan Package</td>
</tr>
<tr>
<th>Thermal Component Width</th>
<td>24.0&quot;</td>
</tr>
<tr>
<th>Thermal Component Height</th>
<td>49.0&quot;</td>
</tr>
<tr>
<th>Thermal Component Rack Units</th>
<td>26</td>
</tr>
<tr>
<th>Line</th>
<td>Protek</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Window door, made of .25-inch scratch-resistant safety glass and mechanically fastened, provides visual monitoring of internal equipment while maintaining equipment protection</p>
<p>Integral top solar/drip shield</p>
<p>Two thermostatically controlled, long-life, high-performance fans mounted into top</p>
<p>All seams are fully welded and ground smooth</p>
<p>Solid door provides complete physical and visual protection</p>
<p>Front and rear access to 19-inch rack equipment provided by three-part design: door, center section and wall section</p>
<p>Perforated, vented base with internal, expanded metal, serviceable filter</p>
<p>One set of plated, self-grounding, tapped 10-32 rack angles per EIA universal spacing standards, adjustable front-to-back within the center section of the cabinet</p>
<p>Key-locking wing knob provides access control to the cabinet, two keys are included with each cabinet</p>
<p>Premium seamless, foam-in-place gasket prevents contaminants from entering the cabinet</p>
<p>Door, center section and wall section are provided with ground studs to facilitate proper bonding and grounding of the cabinet</p>
<p>Additional rack angles in tapped- or square-hole versions can be added to the cabinet</p>
<p>Wall section welded panel studs which accommodate standard panels (steel and wood available), can be ordered separately</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-pthw482424gf-490x240x250-protek-doublehinged-fan-packages/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>nVent Hoffman PTHS482424G3 49.0&#8243;x24.0&#8243;x25.0&#8243; ProTek Double-Hinged Fan Packages</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-pths482424g3-490x240x250-protek-doublehinged-fan-packages/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-pths482424g3-490x240x250-protek-doublehinged-fan-packages/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:50 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-pths482424g3-49-0x24-0x25-0-protek-double-hinged-fan-packages/</guid>

					<description><![CDATA[<p>nVent Hoffman PTHS482424G3 49.0″x24.0″x25.0″ Wall Mount ProTek Double-Hinged Fan Packages</p>]]></description>
										<content:encoded><![CDATA[<p>nVent Hoffman PTHS482424G3 49.0&quot;x24.0&quot;x25.0&quot; Wall Mount ProTek Double-Hinged Fan Packages</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Fan Package</td>
</tr>
<tr>
<th>Thermal Component Width</th>
<td>24.0&quot;</td>
</tr>
<tr>
<th>Thermal Component Height</th>
<td>49.0&quot;</td>
</tr>
<tr>
<th>Thermal Component Rack Units</th>
<td>26</td>
</tr>
<tr>
<th>Line</th>
<td>Protek</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Window door, made of .25-inch scratch-resistant safety glass and mechanically fastened, provides visual monitoring of internal equipment while maintaining equipment protection</p>
<p>Integral top solar/drip shield</p>
<p>Two thermostatically controlled, long-life, high-performance fans mounted into top</p>
<p>All seams are fully welded and ground smooth</p>
<p>Solid door provides complete physical and visual protection</p>
<p>Front and rear access to 19-inch rack equipment provided by three-part design: door, center section and wall section</p>
<p>Perforated, vented base with internal, expanded metal, serviceable filter</p>
<p>One set of plated, self-grounding, tapped 10-32 rack angles per EIA universal spacing standards, adjustable front-to-back within the center section of the cabinet</p>
<p>Key-locking wing knob provides access control to the cabinet, two keys are included with each cabinet</p>
<p>Premium seamless, foam-in-place gasket prevents contaminants from entering the cabinet</p>
<p>Door, center section and wall section are provided with ground studs to facilitate proper bonding and grounding of the cabinet</p>
<p>Additional rack angles in tapped- or square-hole versions can be added to the cabinet</p>
<p>Wall section welded panel studs which accommodate standard panels (steel and wood available), can be ordered separately</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-pths482424g3-490x240x250-protek-doublehinged-fan-packages/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>nVent Hoffman UVT2552 &#8211; Ventilation module, 255mm</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-uvt2552-ventilation-module-255mm/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-uvt2552-ventilation-module-255mm/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:49 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-uvt2552-ventilation-module-255mm/</guid>

					<description><![CDATA[<p>nVent Hoffman UVT2552 - Ventilation module, 255mm</p>]]></description>
										<content:encoded><![CDATA[<p>nVent Hoffman UVT2552 &#8211; Ventilation module, 255mm</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Ventilation Module</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Description: Ventilation shelf with controller that regulates the temperature and air flow inside the racks. The unit consists of a fan controller and 2 or 4 fans inside a one unit shelf. The electronic sensor can be attached where the temperature is most critical (hot spot), close to your most expensive equipment, to ensure the correct temperature and air flow. The current temperature is displayed on the front of the unit, where it is possible to see preset values and intervals. The presence of&#8230; an automatic control allows the system to switch on the ventilation only when the temperature goes beyond the operator preset value Thereby the equipment gets less dusty and the energy consumption is reduced as well as the sound level. In other words the ventilation system saves energy, but also prolongs the life of the ventilators, which are operating only when needed. Fully wired and ready to connect.</p>
<p>Voltage: 200-235 V.</p>
<p>Alternating current frequency: 50~60 Hz.</p>
<p>Power of the fan: 22 Watt.</p>
<p>Consumption current: 0.28A / 0.56A.</p>
<p>Air circulation: 4.4 / 8.8 m³/min.</p>
<p>Measurement limits: -50 ºC &#8230; +125 ºC.</p>
<p>Measurement accuracy: +/-0.5ºC.</p>
<p>Working temperature: 0&#8230;+50ºC.</p>
<p>Relative air humidity (air temp. +35C): 80%.</p>
<p>Noise level: 35 decibel.</p>
<p>Lifetime: 30.000 hours.</p>
<p>Approvals: UL, CSA, VDE, TUV.</p>
<p>Switch: No.</p>
<p>Pack quantity: 1 unit including power cable (1.5 m) with Shuko plug and sensor cable (1.2 m). Version with 4 fans is supplied with a depth fixing bracket.</p>
<p>Thermostat: Yes.</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-uvt2552-ventilation-module-255mm/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>nVent Hoffman CDU800H3SBB RackChiller CDU800 Coolant Distribution Unit</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3sbb-rackchiller-cdu800-coolant-distribution-unit/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3sbb-rackchiller-cdu800-coolant-distribution-unit/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:48 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-cdu800h3sbb-rackchiller-cdu800-coolant-distribution-unit/</guid>

					<description><![CDATA[<p>The nVent HOFFMAN RackChiller CDU800 is designed for efficient and safe supply of IT equipment. The entire system is focused on providing the highest reliability, availability, and serviceability for supporting direct-to-chip liquid cooling. The CDU800 is fed from a primary facility water system (FWS), where the…</p>]]></description>
										<content:encoded><![CDATA[<p>The nVent HOFFMAN RackChiller CDU800 is designed for efficient and safe supply of IT equipment. The entire system is focused on providing the highest reliability, availability, and serviceability for supporting direct-to-chip liquid cooling. The CDU800 is fed from a primary facility water system (FWS), where the integrated pumps drive the secondary technology cooling system (TCS) cooling loop flow. The heat exchanger transfers the excess heat from the secondary coolant to the primary. The complete system is integrated into an aesthetical enclosure with removable side panels and doors. The CDU can be installed onto a slab or raised floor, in-row with equipment racks or into a separate facility room.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Coolant Distribution Unit</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Redundant high-performance, leak-free pump system</p>
<p>Integrated variable speed drives</p>
<p>Coolant connections through top or bottom panel</p>
<p>Integrated 10 inch touch panel display</p>
<p>Remote control features through Ethernet, SNMP v3, Modbus</p>
<p>On-board integrated leak detection</p>
<p>Unrivaled power density – fits into standard data center footprint</p>
<p>Serviceable during operation – no need for shut down during system maintenance</p>
<p>Redundant system layout minimizes risk for single points of failure</p>
<p>Integrates with nVent Guardian Management Gateway and sensors portfolio</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3sbb-rackchiller-cdu800-coolant-distribution-unit/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>nVent Hoffman CDU800H3PBB RackChiller CDU800 Coolant Distribution Unit</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3pbb-rackchiller-cdu800-coolant-distribution-unit/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3pbb-rackchiller-cdu800-coolant-distribution-unit/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:48 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-cdu800h3pbb-rackchiller-cdu800-coolant-distribution-unit/</guid>

					<description><![CDATA[<p>The nVent HOFFMAN RackChiller CDU800 is designed for efficient and safe supply of IT equipment. The entire system is focused on providing the highest reliability, availability, and serviceability for supporting direct-to-chip liquid cooling. The CDU800 is fed from a primary facility water system (FWS), where the…</p>]]></description>
										<content:encoded><![CDATA[<p>The nVent HOFFMAN RackChiller CDU800 is designed for efficient and safe supply of IT equipment. The entire system is focused on providing the highest reliability, availability, and serviceability for supporting direct-to-chip liquid cooling. The CDU800 is fed from a primary facility water system (FWS), where the integrated pumps drive the secondary technology cooling system (TCS) cooling loop flow. The heat exchanger transfers the excess heat from the secondary coolant to the primary. The complete system is integrated into an aesthetical enclosure with removable side panels and doors. The CDU can be installed onto a slab or raised floor, in-row with equipment racks or into a separate facility room.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Coolant Distribution Unit</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Redundant high-performance, leak-free pump system</p>
<p>Integrated variable speed drives</p>
<p>Coolant connections through top or bottom panel</p>
<p>Integrated 10 inch touch panel display</p>
<p>Remote control features through Ethernet, SNMP v3, Modbus</p>
<p>On-board integrated leak detection</p>
<p>Unrivaled power density – fits into standard data center footprint</p>
<p>Serviceable during operation – no need for shut down during system maintenance</p>
<p>Redundant system layout minimizes risk for single points of failure</p>
<p>Integrates with nVent Guardian Management Gateway and sensors portfolio</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3pbb-rackchiller-cdu800-coolant-distribution-unit/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>nVent Hoffman CDU800H3STB RackChiller CDU800 Coolant Distribution Unit</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3stb-rackchiller-cdu800-coolant-distribution-unit/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3stb-rackchiller-cdu800-coolant-distribution-unit/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:47 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-cdu800h3stb-rackchiller-cdu800-coolant-distribution-unit/</guid>

					<description><![CDATA[<p>The nVent HOFFMAN RackChiller CDU800 is designed for efficient and safe supply of IT equipment. The entire system is focused on providing the highest reliability, availability, and serviceability for supporting direct-to-chip liquid cooling. The CDU800 is fed from a primary facility water system (FWS), where the…</p>]]></description>
										<content:encoded><![CDATA[<p>The nVent HOFFMAN RackChiller CDU800 is designed for efficient and safe supply of IT equipment. The entire system is focused on providing the highest reliability, availability, and serviceability for supporting direct-to-chip liquid cooling. The CDU800 is fed from a primary facility water system (FWS), where the integrated pumps drive the secondary technology cooling system (TCS) cooling loop flow. The heat exchanger transfers the excess heat from the secondary coolant to the primary. The complete system is integrated into an aesthetical enclosure with removable side panels and doors. The CDU can be installed onto a slab or raised floor, in-row with equipment racks or into a separate facility room.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Coolant Distribution Unit</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Redundant high-performance, leak-free pump system</p>
<p>Integrated variable speed drives</p>
<p>Coolant connections through top or bottom panel</p>
<p>Integrated 10 inch touch panel display</p>
<p>Remote control features through Ethernet, SNMP v3, Modbus</p>
<p>On-board integrated leak detection</p>
<p>Unrivaled power density – fits into standard data center footprint</p>
<p>Serviceable during operation – no need for shut down during system maintenance</p>
<p>Redundant system layout minimizes risk for single points of failure</p>
<p>Integrates with nVent Guardian Management Gateway and sensors portfolio</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3stb-rackchiller-cdu800-coolant-distribution-unit/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>nVent Hoffman UVT4554 &#8211; Ventilation module, 455-670mm</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-uvt4554-ventilation-module-455670mm/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-uvt4554-ventilation-module-455670mm/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:47 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-uvt4554-ventilation-module-455-670mm/</guid>

					<description><![CDATA[<p>nVent Hoffman UVT4554 - Ventilation module, 455-670mm</p>]]></description>
										<content:encoded><![CDATA[<p>nVent Hoffman UVT4554 &#8211; Ventilation module, 455-670mm</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Ventilation Module</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Description: Ventilation shelf with controller that regulates the temperature and air flow inside the racks. The unit consists of a fan controller and 2 or 4 fans inside a one unit shelf. The electronic sensor can be attached where the temperature is most critical (hot spot), close to your most expensive equipment, to ensure the correct temperature and air flow. The current temperature is displayed on the front of the unit, where it is possible to see preset values and intervals. The presence of&#8230; an automatic control allows the system to switch on the ventilation only when the temperature goes beyond the operator preset value Thereby the equipment gets less dusty and the energy consumption is reduced as well as the sound level. In other words the ventilation system saves energy, but also prolongs the life of the ventilators, which are operating only when needed. Fully wired and ready to connect.</p>
<p>Voltage: 200-235 V.</p>
<p>Alternating current frequency: 50~60 Hz.</p>
<p>Power of the fan: 22 Watt.</p>
<p>Consumption current: 0.28A / 0.56A.</p>
<p>Air circulation: 4.4 / 8.8 m³/min.</p>
<p>Measurement limits: -50 ºC &#8230; +125 ºC.</p>
<p>Measurement accuracy: +/-0.5ºC.</p>
<p>Working temperature: 0&#8230;+50ºC.</p>
<p>Relative air humidity (air temp. +35C): 80%.</p>
<p>Noise level: 35 decibel.</p>
<p>Lifetime: 30.000 hours.</p>
<p>Approvals: UL, CSA, VDE, TUV.</p>
<p>Switch: No.</p>
<p>Pack quantity: 1 unit including power cable (1.5 m) with Shuko plug and sensor cable (1.2 m). Version with 4 fans is supplied with a depth fixing bracket.</p>
<p>Thermostat: Yes.</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-uvt4554-ventilation-module-455670mm/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>nVent Hoffman CDU800H3PTB RackChiller CDU800 Coolant Distribution Unit</title>
		<link>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3ptb-rackchiller-cdu800-coolant-distribution-unit/</link>
					<comments>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3ptb-rackchiller-cdu800-coolant-distribution-unit/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:28:46 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/nvent-hoffman-cdu800h3ptb-rackchiller-cdu800-coolant-distribution-unit/</guid>

					<description><![CDATA[<p>The nVent HOFFMAN RackChiller CDU800 is designed for efficient and safe supply of IT equipment. The entire system is focused on providing the highest reliability, availability, and serviceability for supporting direct-to-chip liquid cooling. The CDU800 is fed from a primary facility water system (FWS), where the…</p>]]></description>
										<content:encoded><![CDATA[<p>The nVent HOFFMAN RackChiller CDU800 is designed for efficient and safe supply of IT equipment. The entire system is focused on providing the highest reliability, availability, and serviceability for supporting direct-to-chip liquid cooling. The CDU800 is fed from a primary facility water system (FWS), where the integrated pumps drive the secondary technology cooling system (TCS) cooling loop flow. The heat exchanger transfers the excess heat from the secondary coolant to the primary. The complete system is integrated into an aesthetical enclosure with removable side panels and doors. The CDU can be installed onto a slab or raised floor, in-row with equipment racks or into a separate facility room.</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Component</th>
<td>Coolant Distribution Unit</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Hoffman</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Redundant high-performance, leak-free pump system</p>
<p>Integrated variable speed drives</p>
<p>Coolant connections through top or bottom panel</p>
<p>Integrated 10 inch touch panel display</p>
<p>Remote control features through Ethernet, SNMP v3, Modbus</p>
<p>On-board integrated leak detection</p>
<p>Unrivaled power density – fits into standard data center footprint</p>
<p>Serviceable during operation – no need for shut down during system maintenance</p>
<p>Redundant system layout minimizes risk for single points of failure</p>
<p>Integrates with nVent Guardian Management Gateway and sensors portfolio</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/nvent-hoffman-cdu800h3ptb-rackchiller-cdu800-coolant-distribution-unit/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
