<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Disconnects &#8211; Erik Prayoga</title>
	<atom:link href="https://erik-prayoga.com/product-category/circuit-breakers-fuses/disconnects/feed/" rel="self" type="application/rss+xml" />
	<link>https://erik-prayoga.com</link>
	<description></description>
	<lastBuildDate>Mon, 22 Jun 2026 06:50:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://erik-prayoga.com/wp-content/uploads/2026/10/cropped-erik-logo-copy-32x32.png</url>
	<title>Disconnects &#8211; Erik Prayoga</title>
	<link>https://erik-prayoga.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Siemens DTNF366R Non-Fusible Heavy Duty Safety Switch &#8211; 600 Amp, 600 VAC, Three Pole, NEMA 3R</title>
		<link>https://erik-prayoga.com/product/siemens-dtnf366r-nonfusible-heavy-duty-safety-switch-600-amp-600-vac-three/</link>
					<comments>https://erik-prayoga.com/product/siemens-dtnf366r-nonfusible-heavy-duty-safety-switch-600-amp-600-vac-three/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:50:00 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-dtnf366r-non-fusible-heavy-duty-safety-switch-600-amp-600-vac-three-pole-nema-3r/</guid>

					<description><![CDATA[<p>Siemens DTNF366R Non-Fusible Heavy Duty Safety Switch - 600 Amp, 600 VAC, Three Pole, NEMA 3R - 73″ x 45″ x 19″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens DTNF366R Non-Fusible Heavy Duty Safety Switch &#8211; 600 Amp, 600 VAC, Three Pole, NEMA 3R &#8211; 73&quot; x 45&quot; x 19&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 3R</td>
</tr>
<tr>
<th>Component</th>
<td>Non-Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Voltage</th>
<td>600 VAC</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Current</th>
<td>600 Amp</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-dtnf366r-nonfusible-heavy-duty-safety-switch-600-amp-600-vac-three/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens HFC328NR Fusible Heavy Duty Safety Switch &#8211; 1200 Amp, 240 VAC, Three Pole, NEMA 3R</title>
		<link>https://erik-prayoga.com/product/siemens-hfc328nr-fusible-heavy-duty-safety-switch-1200-amp-240-vac-three/</link>
					<comments>https://erik-prayoga.com/product/siemens-hfc328nr-fusible-heavy-duty-safety-switch-1200-amp-240-vac-three/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:49:59 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-hfc328nr-fusible-heavy-duty-safety-switch-1200-amp-240-vac-three-pole-nema-3r/</guid>

					<description><![CDATA[<p>Siemens HFC328NR Fusible Heavy Duty Safety Switch - 1200 Amp, 240 VAC, Three Pole, NEMA 3R - 7.56″ x 7.56″ x 6.27″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens HFC328NR Fusible Heavy Duty Safety Switch &#8211; 1200 Amp, 240 VAC, Three Pole, NEMA 3R &#8211; 7.56&quot; x 7.56&quot; x 6.27&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Voltage</th>
<td>240 VAC</td>
</tr>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 3R</td>
</tr>
<tr>
<th>Component</th>
<td>Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Current</th>
<td>1200 Amp</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-hfc328nr-fusible-heavy-duty-safety-switch-1200-amp-240-vac-three/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens HFC365NSWA Fusible Heavy Duty Safety Switch &#8211; 400 Amp, 600 VAC, Three Pole, NEMA 4X</title>
		<link>https://erik-prayoga.com/product/siemens-hfc365nswa-fusible-heavy-duty-safety-switch-400-amp-600-vac-three/</link>
					<comments>https://erik-prayoga.com/product/siemens-hfc365nswa-fusible-heavy-duty-safety-switch-400-amp-600-vac-three/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:49:59 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-hfc365nswa-fusible-heavy-duty-safety-switch-400-amp-600-vac-three-pole-nema-4x/</guid>

					<description><![CDATA[<p>Siemens HFC365NSWA Fusible Heavy Duty Safety Switch - 400 Amp, 600 VAC, Three Pole, NEMA 4X - 7.34″ x 22.4″ x 45.32″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens HFC365NSWA Fusible Heavy Duty Safety Switch &#8211; 400 Amp, 600 VAC, Three Pole, NEMA 4X &#8211; 7.34&quot; x 22.4&quot; x 45.32&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 4X</td>
</tr>
<tr>
<th>Component</th>
<td>Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Voltage</th>
<td>600 VAC</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Current</th>
<td>400 Amp</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-hfc365nswa-fusible-heavy-duty-safety-switch-400-amp-600-vac-three/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens HNF365SSWA Non-Fusible Heavy Duty Safety Switch &#8211; 400 Amp, 600 VAC, Three Pole, NEMA 4X</title>
		<link>https://erik-prayoga.com/product/siemens-hnf365sswa-nonfusible-heavy-duty-safety-switch-400-amp-600-vac/</link>
					<comments>https://erik-prayoga.com/product/siemens-hnf365sswa-nonfusible-heavy-duty-safety-switch-400-amp-600-vac/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:49:59 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-hnf365sswa-non-fusible-heavy-duty-safety-switch-400-amp-600-vac-three-pole-nema-4x/</guid>

					<description><![CDATA[<p>Siemens HNF365SSWA Non-Fusible Heavy Duty Safety Switch - 400 Amp, 600 VAC, Three Pole, NEMA 4X - 33.47″ x 22.4″ x 7.34″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens HNF365SSWA Non-Fusible Heavy Duty Safety Switch &#8211; 400 Amp, 600 VAC, Three Pole, NEMA 4X &#8211; 33.47&quot; x 22.4&quot; x 7.34&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 4X</td>
</tr>
<tr>
<th>Component</th>
<td>Non-Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Voltage</th>
<td>600 VAC</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Current</th>
<td>400 Amp</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-hnf365sswa-nonfusible-heavy-duty-safety-switch-400-amp-600-vac/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens HF367NRW Fusible Heavy Duty Safety Switch &#8211; 800 Amp, 600 VAC, Three Pole, NEMA 12</title>
		<link>https://erik-prayoga.com/product/siemens-hf367nrw-fusible-heavy-duty-safety-switch-800-amp-600-vac-three/</link>
					<comments>https://erik-prayoga.com/product/siemens-hf367nrw-fusible-heavy-duty-safety-switch-800-amp-600-vac-three/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:49:58 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-hf367nrw-fusible-heavy-duty-safety-switch-800-amp-600-vac-three-pole-nema-12/</guid>

					<description><![CDATA[<p>Siemens HF367NRW Fusible Heavy Duty Safety Switch - 800 Amp, 600 VAC, Three Pole, NEMA 12 - 72″ x 42″ x 18″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens HF367NRW Fusible Heavy Duty Safety Switch &#8211; 800 Amp, 600 VAC, Three Pole, NEMA 12 &#8211; 72&quot; x 42&quot; x 18&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 12</td>
</tr>
<tr>
<th>Component</th>
<td>Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Voltage</th>
<td>600 VAC</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Current</th>
<td>800 Amp</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-hf367nrw-fusible-heavy-duty-safety-switch-800-amp-600-vac-three/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens HF325SSA Fusible Heavy Duty Safety Switch &#8211; 400 Amp, 240 VAC, Three Pole, NEMA 4X</title>
		<link>https://erik-prayoga.com/product/siemens-hf325ssa-fusible-heavy-duty-safety-switch-400-amp-240-vac-three/</link>
					<comments>https://erik-prayoga.com/product/siemens-hf325ssa-fusible-heavy-duty-safety-switch-400-amp-240-vac-three/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:49:57 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-hf325ssa-fusible-heavy-duty-safety-switch-400-amp-240-vac-three-pole-nema-4x/</guid>

					<description><![CDATA[<p>Siemens HF325SSA Fusible Heavy Duty Safety Switch - 400 Amp, 240 VAC, Three Pole, NEMA 4X - 45.32″ x 22.4″ x 7.34″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens HF325SSA Fusible Heavy Duty Safety Switch &#8211; 400 Amp, 240 VAC, Three Pole, NEMA 4X &#8211; 45.32&quot; x 22.4&quot; x 7.34&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Voltage</th>
<td>240 VAC</td>
</tr>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 4X</td>
</tr>
<tr>
<th>Component</th>
<td>Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Current</th>
<td>400 Amp</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-hf325ssa-fusible-heavy-duty-safety-switch-400-amp-240-vac-three/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens HF367JW Fusible Heavy Duty Safety Switch &#8211; 800 Amp, 600 VAC, Three Pole, NEMA 12</title>
		<link>https://erik-prayoga.com/product/siemens-hf367jw-fusible-heavy-duty-safety-switch-800-amp-600-vac-three/</link>
					<comments>https://erik-prayoga.com/product/siemens-hf367jw-fusible-heavy-duty-safety-switch-800-amp-600-vac-three/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:49:56 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-hf367jw-fusible-heavy-duty-safety-switch-800-amp-600-vac-three-pole-nema-12/</guid>

					<description><![CDATA[<p>Siemens HF367JW Fusible Heavy Duty Safety Switch - 800 Amp, 600 VAC, Three Pole, NEMA 12 - 72″ x 42″ x 18″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens HF367JW Fusible Heavy Duty Safety Switch &#8211; 800 Amp, 600 VAC, Three Pole, NEMA 12 &#8211; 72&quot; x 42&quot; x 18&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 12</td>
</tr>
<tr>
<th>Component</th>
<td>Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Voltage</th>
<td>600 VAC</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Current</th>
<td>800 Amp</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-hf367jw-fusible-heavy-duty-safety-switch-800-amp-600-vac-three/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens HF328NR Fusible Heavy Duty Safety Switch &#8211; 1200 Amp, 240 VAC, Three Pole, NEMA 3R</title>
		<link>https://erik-prayoga.com/product/siemens-hf328nr-fusible-heavy-duty-safety-switch-1200-amp-240-vac-three/</link>
					<comments>https://erik-prayoga.com/product/siemens-hf328nr-fusible-heavy-duty-safety-switch-1200-amp-240-vac-three/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:49:56 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-hf328nr-fusible-heavy-duty-safety-switch-1200-amp-240-vac-three-pole-nema-3r/</guid>

					<description><![CDATA[<p>Siemens HF328NR Fusible Heavy Duty Safety Switch - 1200 Amp, 240 VAC, Three Pole, NEMA 3R - 75″ x 43″ x 12″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens HF328NR Fusible Heavy Duty Safety Switch &#8211; 1200 Amp, 240 VAC, Three Pole, NEMA 3R &#8211; 75&quot; x 43&quot; x 12&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Voltage</th>
<td>240 VAC</td>
</tr>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 3R</td>
</tr>
<tr>
<th>Component</th>
<td>Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Current</th>
<td>1200 Amp</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-hf328nr-fusible-heavy-duty-safety-switch-1200-amp-240-vac-three/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens HNF368RW Non-Fusible Heavy Duty Safety Switch &#8211; 1200 Amp, 600 VAC, Three Pole, NEMA 3R</title>
		<link>https://erik-prayoga.com/product/siemens-hnf368rw-nonfusible-heavy-duty-safety-switch-1200-amp-600-vac/</link>
					<comments>https://erik-prayoga.com/product/siemens-hnf368rw-nonfusible-heavy-duty-safety-switch-1200-amp-600-vac/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:49:55 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-hnf368rw-non-fusible-heavy-duty-safety-switch-1200-amp-600-vac-three-pole-nema-3r/</guid>

					<description><![CDATA[<p>Siemens HNF368RW Non-Fusible Heavy Duty Safety Switch - 1200 Amp, 600 VAC, Three Pole, NEMA 3R - 60″ x 42″ x 18″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens HNF368RW Non-Fusible Heavy Duty Safety Switch &#8211; 1200 Amp, 600 VAC, Three Pole, NEMA 3R &#8211; 60&quot; x 42&quot; x 18&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 3R</td>
</tr>
<tr>
<th>Component</th>
<td>Non-Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Voltage</th>
<td>600 VAC</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Current</th>
<td>1200 Amp</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-hnf368rw-nonfusible-heavy-duty-safety-switch-1200-amp-600-vac/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Siemens HFC368R Fusible Heavy Duty Safety Switch &#8211; 1200 Amp, 600 VAC, Three Pole, NEMA 3R</title>
		<link>https://erik-prayoga.com/product/siemens-hfc368r-fusible-heavy-duty-safety-switch-1200-amp-600-vac-three/</link>
					<comments>https://erik-prayoga.com/product/siemens-hfc368r-fusible-heavy-duty-safety-switch-1200-amp-600-vac-three/#respond</comments>
		
		<dc:creator><![CDATA[Erik Prayoga]]></dc:creator>
		<pubDate>Mon, 22 Jun 2026 06:49:55 +0000</pubDate>
				<guid isPermaLink="false">https://deddysusanto.com/product/siemens-hfc368r-fusible-heavy-duty-safety-switch-1200-amp-600-vac-three-pole-nema-3r/</guid>

					<description><![CDATA[<p>Siemens HFC368R Fusible Heavy Duty Safety Switch - 1200 Amp, 600 VAC, Three Pole, NEMA 3R - 7.56″ x 7.56″ x 6.27″ (LxWxH)</p>]]></description>
										<content:encoded><![CDATA[<p>Siemens HFC368R Fusible Heavy Duty Safety Switch &#8211; 1200 Amp, 600 VAC, Three Pole, NEMA 3R &#8211; 7.56&quot; x 7.56&quot; x 6.27&quot; (LxWxH)</p>
<h3>Specifications</h3>
<table>
<tbody>
<tr>
<th>Enclosure NEMA Rating</th>
<td>NEMA 3R</td>
</tr>
<tr>
<th>Component</th>
<td>Fusible Disconnect Switch</td>
</tr>
<tr>
<th>Voltage</th>
<td>600 VAC</td>
</tr>
<tr>
<th>Manufacturer</th>
<td>Siemens</td>
</tr>
<tr>
<th>Enclosure Disconnect Type</th>
<td>Heavy Duty Safety Switch</td>
</tr>
<tr>
<th>Current</th>
<td>1200 Amp</td>
</tr>
<tr>
<th>Poles</th>
<td>3 Pole</td>
</tr>
</tbody>
</table>
<h3>Features</h3>
<div>
<p>Heavy Duty Safety Switches are available in 30 -1200 A ratings, in Type 1, 3R, 12 and 4X enclosures and in 2, 3, 4 and 6 pole versions.</p>
<p>Fusible models are available for either 240 V AC max. or 600 V AC or 600 V DC applications. Non-fusible versions are available in 600 V AC max ratings and can be used on any AC voltage through 600 V AC.</p>
<p>Fusible versions accept Class H fuses as standard in 30-600 A ratings and can be converted to Class R fusing only with a field installed kit. 600 V rated fusible switches in 30-600 A ratings can be converted to accept Class J fuses by simply moving their load base. 800 and 1200 A fusible switches accept Class L fuses.</p>
<p>All accept aux contact kits. Neutrals are either factory installed or can be field added. All are UL98 listed (rotary switches are UL508 listed and solar disconnects are listed as UL1741 PV switches).</p>
</div>
<div>
]]></content:encoded>
					
					<wfw:commentRss>https://erik-prayoga.com/product/siemens-hfc368r-fusible-heavy-duty-safety-switch-1200-amp-600-vac-three/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
